Product Description
Implant Analog for Implant H2.43
The Implant Analog for Implant H2.43 is a precision laboratory component designed to accurately reproduce the position and connection geometry of dental implants with H2.43 internal hex connection within a dental working model during prosthetic fabrication procedures.
The analogue replicates the 2.43 mm internal hex implant connection, enabling precise positioning of prosthetic components and accurate laboratory simulation of the clinical implant situation.
Manufactured with high dimensional accuracy, the implant analogue is intended for use in the fabrication of implant-supported restorations, including crowns, bridges, bars, and other prosthetic structures.
Produced from high-quality stainless steel, the analogue provides excellent dimensional stability, corrosion resistance, mechanical strength, and durability throughout laboratory procedures.
The component is compatible with implant systems featuring H2.43 internal connection geometry.
Specifications
- Connection: Internal Hex H2.43
- Material: Stainless steel
- Application: Dental laboratory use
- Compatibility: H2.43 implant systems
Indications for Use
Intended for use in dental laboratories for:
- Working model fabrication
- Implant-supported prosthetic restorations
- Crown and bridge fabrication
- Laboratory simulation of implant position
- Implant prosthetic workflows
- Restorative laboratory procedures
Compatible with:
- UNIQUE implants: 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- PERFECT implants: 4.2 mm, 5.0 mm, 6.0 m
- PRIMA implants: 3.3 mm, 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- Other implant systems with H2.43 internal connection
Features
- Precision-machined implant connection geometry
- Accurate reproduction of implant position
- Compatible with H2.43 internal hex implant connection
- Excellent dimensional stability
- Durable stainless steel construction
- Reliable fit with prosthetic components
- Optimized for laboratory workflows
- High restorative accuracy
Advantages
- Precise laboratory replication of implant position
- Supports accurate prosthetic fabrication
- Stable connection geometry for reliable component fit
- High mechanical durability
- Corrosion-resistant stainless steel construction
- Compatible with multiple implant systems
- Designed for predictable restorative outcomes
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Implant Analog for Implant H2.43
General Information
Before using DMi products, the dentist, maxillofacial surgeon, or dental technician should carefully read the indications, contraindications, recommendations, warnings, and instructions, as well as all additional product information, including product descriptions, surgical and prosthetic manuals, catalogs, and related documentation.
DMi also recommends participation in relevant continuing education courses conducted on-site or remotely by authorized DMi specialists.
Detailed documentation and training information are available through authorized DMi representatives and on the company website:
www.dmimplant.online
Product Description
The Implant Analog for Implant H2.43 is a precision laboratory component intended to reproduce the exact position and connection geometry of a dental implant with H2.43 internal hex connection within a dental working model.
The analogue simulates the intraosseous portion of the implant and is used during prosthetic and laboratory procedures for fabrication of implant-supported restorations.
The component features a precision-machined 2.43 mm internal hex connection designed for accurate fit and compatibility with prosthetic components and impression transfers.
Manufactured from high-quality stainless steel, the implant analogue provides:
- Excellent dimensional stability
- High mechanical strength
- Corrosion resistance
- Long-term laboratory durability
Technical Specifications
- Connection: Internal Hex H2.43
- Material: Stainless steel
- Application: Dental laboratory procedures
- Compatibility: H2.43 implant systems
Compatible with:
- UNIQUE implants: 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- PERFECT implants: 4.2 mm, 5.0 mm, 6.0 mm
- PRIMA implants: 3.3 mm, 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- Other implant systems with H2.43 internal connection
Warnings
- Intended for laboratory use only.
- The product is supplied non-sterile.
- The analogue is not intended for intraoral implantation.
- Improper handling may affect laboratory accuracy and prosthetic fit.
- Only compatible components and instruments should be used.
Indications
The implant analogue is intended for:
- Fabrication of dental working models
- Implant-supported prosthetic restorations
- Crown and bridge laboratory procedures
- Implant prosthetic simulations
- Reproduction of implant position within plaster models
Contraindications
- Use with incompatible implant systems
- Use of damaged or deformed components
- Improper laboratory procedures affecting restoration accuracy
Procedure for Use
Laboratory Procedure
1. After obtaining the implant impression, connect the Implant Analog for Implant H2.43 to the corresponding impression transfer.
2. Ensure complete and accurate seating of the analogue within the transfer connection.
3. Insert the assembled transfer and analogue into the corresponding position within the impression.
4. Verify stable and precise positioning before pouring the model.
5. Apply gingival mask material if required for prosthetic procedures.
6. Pour the impression using appropriate dental stone or laboratory plaster.
7. After complete hardening of the model, separate the impression from the cast.
8. The implant analogue remains embedded within the model, accurately reproducing the clinical implant position.
9. The resulting working model is used for fabrication of implant-supported restorations.
Sterilization
- The Implant Analog for Implant H2.43 is supplied non-sterile.
- If sterilization is required, steam sterilization in an autoclave at 135°C (275°F) is recommended before use.
- Store in a clean, dry environment.
CadCam