Product Description
Closed Clip Transfer for Implant H2.43
The Closed Clip Transfer for Implant H2.43 is a precision impression component designed for accurate transfer of the intraoral position of osseointegrated implants to the working model during prosthetic procedures using the closed tray impression technique.
The transfer is directly retained within the internal implant connection without the use of a fixation screw. Stable positioning is achieved through an integrated retention clip mechanism, providing secure fixation during impression procedures and reliable transfer accuracy.
Manufactured from high-quality stainless steel, the component provides excellent dimensional stability, corrosion resistance, mechanical strength, and durability during clinical use.
The transfer is intended for use with implants featuring H2.43 internal connection and is compatible with multiple implant systems for closed tray impression procedures in all regions of the upper and lower jaw.
Key Features
- Designed for closed tray impression technique
- Direct retention without fixation screw
- Integrated clip retention mechanism
- Compatible with H2.43 internal implant connection
- Precision-machined stainless steel construction
- Stable positioning during impression procedures
- Designed for accurate implant transfer
- Suitable for upper and lower jaw applications
Available Versions / References
Implant connection: H2.43 internal connection
Compatible Implant Systems
- UNIQUE Implant: 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- PERFECT Implant: 4.2 mm, 5.0 mm, 6.0 mm
- PRIMA Implant: 3.3 mm, 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- Compatible with all osseointegrated implants featuring H2.43 internal connection
Technical Specifications
- Diameter: 4.5 mm
- Height: 13 mm
- Implant connection: H2.43 internal connection
Material
- Manufactured from high-quality stainless steel, providing:
- High mechanical strength
- Corrosion resistance
- Excellent dimensional stability
- Precision and durability for clinical use
Clinical / Laboratory Application
- Closed tray implant impression procedures
- Transfer of implant position to laboratory model
- Implant-supported restorative workflows
- Prosthetic rehabilitation on osseointegrated implants
- Upper and lower jaw implant impressions
Sterilization
Before clinical use, the product must be sterilized in an autoclave at 135°C / 274°F.
Advantages
- Screwless retention design for simplified handling
- Reliable clip fixation during impression procedures
- Accurate transfer of implant positioning
- Compatible with multiple implant systems
- Durable stainless steel construction
- Supports predictable prosthetic outcomes
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Closed Clip Transfer for Implant H2.43
General Information
Before using DMi products, the dentist, maxillofacial surgeon, or dental technician should carefully read all indications, contraindications, recommendations, warnings, and instructions for use, as well as all related product documentation including product descriptions, surgical and prosthetic protocols, instrument manuals, and catalogs.
DMi recommends participation in certified educational and training programs conducted by authorized DMi specialists. Additional product information and training resources are available through official DMi representatives and on the company website:
www.dmimplant.online
Intended Use
The Closed Clip Transfer is intended for:
- Closed tray implant impression procedures
- Accurate transfer of implant position from the oral cavity to the working model
- Implant-supported prosthetic rehabilitation
- Prosthetic workflows for osseointegrated implants
Indications
The transfer is indicated for:
- Closed tray implant impressions
- Prosthetic restoration procedures on osseointegrated implants
- Implant-supported restorative workflows
- Transfer of implant position to laboratory models
Contraindications
Do not use the product in cases of:
- Lack of implant osseointegration
- Allergy or hypersensitivity to metals
- Trismus of the masticatory muscles
- Limited mouth opening
- Increased gag reflex
Warnings
- The transfer is intended for single use only.
- The product is supplied non-sterile.
- Sterilization before clinical use is mandatory.
- Recommended sterilization method: autoclave sterilization at 135°C / 274°F.
- The clinician must be properly trained in implant impression techniques and use of the transfer system.
- Use only compatible implant systems and prosthetic components.
Precautions
- Verify compatibility with the implant system before use.
- Inspect the transfer for damage or deformation before use.
- Ensure proper seating of the transfer inside the implant connection.
- Follow standard implant prosthetic and infection control protocols.
Instructions for Clinical Use
1. Preparation
- Remove the gingival former using a 1.27 mm hex driver.
- Clean and dry the implant connection area.
2. Placement of the Transfer
- Insert the Closed Clip Transfer (Ref. 901546) vertically into the implant internal hex connection.
- Ensure the 2.43 mm hex engages fully within the implant.
- The retention clip secures the transfer inside the implant through mechanical retention.
3. Impression Procedure
- Perform the impression using the closed tray “sandwich” technique (two-layer impression method).
Apply:
- Low-viscosity impression material internally
- High-viscosity impression material externally
- Both materials may be inserted simultaneously.
- Medium-viscosity impression material may also be used if clinically indicated.
4. Removal of the Impression
- After polymerization of the impression material, remove the impression from the oral cavity together with the transfer.
5. Laboratory Procedure
- Attach the laboratory analogue for Internal Hex 2.43 implant connection (Ref. 920038, etc.) to the transfer within the impression.
The resulting assembly consists of:
- Impression
- Transfer
- Implant analogue
- Send the completed assembly to the dental laboratory.
6. Model Fabrication
- The dental technician applies gingival mask material around the implant area.
- The impression is poured using dental stone (super plaster).
- After setting, the impression and transfer are separated from the model.
- The implant analogue remains embedded within the model for prosthetic fabrication.
Cleaning and Sterilization
The product must be sterilized before clinical use.
- Sterilization Parameters
- Autoclave sterilization
- Temperature: 135°C / 274°F
Follow validated sterilization procedures according to local regulations and clinical protocols.
Storage
- Store in a clean and dry environment.
- Protect from contamination, moisture, and mechanical damage.
- Avoid exposure to corrosive substances.