Product Description
Straight Titanium Wide Abutment with Shoulder for Implant H2.43
The Straight Titanium Wide Abutment with Shoulder for Implant H2.43 is a prefabricated prosthetic component designed for cement-retained implant restorations. Featuring a straight profile and a wide integrated prosthetic shoulder, this abutment provides a stable and reliable foundation for the fabrication of implant-supported crowns and bridges while supporting optimal soft tissue management and emergence profile development.
Manufactured from medical-grade Ti6Al4V titanium alloy in accordance with ASTM F136 standards, the abutment offers exceptional strength, bio-compatibility, and long-term clinical performance. The component incorporates an anti-rotation H2.43 mm hex connection, ensuring precise positioning and stability throughout restorative treatment.
With a shoulder diameter of 5.6 mm, the abutment is particularly suitable for restorations requiring enhanced prosthetic support and emergence profile control. The abutment connects directly to compatible implants using titanium fixation screw 701203.
Key Features
- Designed for cement-retained restorations
- Straight abutment design
- Wide integrated prosthetic shoulder
- Shoulder diameter: 5.6 mm
- Anti-rotation H2.43 mm hex connection
- Manufactured from Ti6Al4V ASTM F136 medical-grade titanium
- Direct implant connection using screw 701203
- High mechanical strength and corrosion resistance
- Precision-machined implant interface
- Intended for professional dental use
Advantages
- Provides enhanced support for cement-retained restorations
- Wide shoulder design promotes optimal emergence profile development
- Anti-rotation connection ensures accurate prosthetic positioning
- Precision implant interface contributes to predictable restorative outcomes
- Manufactured from biocompatible medical-grade titanium alloy
- Excellent long-term mechanical stability
- Supports aesthetic and functional restoration design
- Simplifies restorative procedures through a prefabricated solution
- Compatible with multiple implant diameters within the H2.43 platform
- Suitable for single-unit and multi-unit restorative applications
Compatible Implant Systems
- UNIQUE Implants Diameters: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PERFECT Implants Diameters: Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PRIMA Implants Diameters: Ø3.3 mm, Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
Sterilization
- The product is supplied non-sterile.
- Before clinical use, the abutment must be sterilized in a steam autoclave using a validated sterilization cycle.
- Recommended sterilization temperature: 135°C (275°F)
Follow the autoclave manufacturer's instructions regarding exposure and drying times.
Applications
The Straight Titanium Wide Abutment with Shoulder for Implant H2.43 is used for the fabrication of cement-retained implant-supported restorations. It provides a stable prosthetic platform for crowns and bridges while supporting functional performance, aesthetic outcomes, and long-term restorative success.
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Straight Titanium Wide Abutment with Shoulder for Implant H2.43
Intended Use
The Straight Titanium Wide Abutment with Shoulder for Implant H2.43 is intended for use as a prosthetic component in the fabrication of cement-retained implant-supported restorations.
Contraindications
Do not use:
- In patients with known hypersensitivity or allergy to titanium alloys.
- With implant systems not listed in these instructions.
- If the component is damaged, deformed, or contaminated.
- If adequate implant stability has not been achieved.
Warnings
- This product is intended for use only by qualified dental professionals.
- Use only original compatible components and fixation screws.
- Improper placement or restoration design may result in prosthetic complications or component failure.
- Ensure complete seating of the abutment before tightening the fixation screw.
- Do not modify the implant connection geometry or anti-rotation feature.
Precautions
- Verify implant compatibility before use.
- Inspect the abutment and fixation screw prior to use.
- Follow accepted prosthetic and restorative procedures.
- Maintain traceability of the product lot number in patient records.
- Ensure proper oral hygiene and routine maintenance following restoration placement.
Instructions for Use
Clinical Procedure
1. Verify compatibility of the abutment with the implant system.
2. Inspect the abutment and fixation screw for damage or contamination.
3. Sterilize the components before clinical use.
4. Seat the abutment onto the implant, ensuring proper engagement of the H2.43 mm hex anti-rotation connection.
5. Insert fixation screw 701203 and tighten according to the implant system's recommended torque value.
6. Verify complete seating and stability of the abutment.
7. Fabricate or place the cement-retained restoration.
8. Remove all excess cement after restoration placement.
9. Verify occlusion, restoration fit, and soft tissue adaptation.
Sterilization
- The product is supplied non-sterile.
- Before clinical use, sterilize the abutment in a steam autoclave using a validated sterilization cycle.
- Recommended sterilization temperature: 135°C (275°F)
Follow the autoclave manufacturer's instructions regarding exposure and drying times.
Storage
Store in a clean, dry environment in the original packaging. Protect from contamination, moisture, and mechanical damage.
CadCam