Product Description
Retrieval Tool Key for Abutment
The Retrieval Tool Key for Abutment is a precision implantology instrument designed for controlled removal and retrieval of implant abutments and prosthetic components during dental implant restorative and maintenance procedures.
The instrument is intended for use in implant prosthetic procedures requiring secure engagement and controlled handling of abutments during removal, replacement, or restorative maintenance operations.
The precision working tip is engineered to provide stable mechanical engagement with compatible implant abutment systems, allowing accurate rotational control and reliable retrieval of prosthetic components during clinical procedures.
The ergonomic instrument design supports improved clinical handling, controlled torque application, and efficient access during implant restorative procedures.
Manufactured from high-quality medical-grade stainless steel, the instrument provides excellent dimensional precision, corrosion resistance, mechanical durability, and long-term clinical reliability.
The Retrieval Tool Key for Abutment is intended for use in implant restorative procedures requiring safe and predictable removal of implant abutments and prosthetic components.
Suitable for:
- Abutment retrieval procedures
- Implant prosthetic maintenance
- Prosthetic component removal
- Implant restorative procedures
- Abutment replacement procedures
- Oral implantology applications
The precision retrieval design allows stable engagement and controlled handling during implant prosthetic procedures.
Specifications
- Instrument type: Retrieval tool key for abutment
- Application: Abutment retrieval and prosthetic maintenance
- Design: Precision engagement working tip
- Compatibility: Implant abutment systems
- Material: Medical-grade stainless steel
- Surface finish: Precision polished surface
- Sterilization: Fully autoclavable
Indications for Use
Intended for:
- Implant abutment retrieval procedures
- Prosthetic component removal
- Implant restorative maintenance
- Abutment replacement procedures
- Implant prosthetic applications
- Oral implantology restorative procedures
Sterilization
The instrument must be sterilized before use in an autoclave at: 135°C (274°F)
Advantages
- Precision abutment retrieval design
- Stable prosthetic component engagement
- Controlled rotational handling
- Reliable implant prosthetic maintenance
- Ergonomic clinical design
- High-strength stainless steel construction
- Excellent corrosion resistance
- Smooth easy-to-clean surface
- Reliable clinical performance
- Fully autoclavable
- Designed for predictable implant restorative procedures
- Suitable for advanced implantology applications
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Retrieval Tool Key for Abutment
Product Description
The Retrieval Tool Key for Abutment is a reusable implantology instrument intended for controlled removal and retrieval of implant abutments and prosthetic components during dental implant restorative and maintenance procedures.
The instrument is designed to provide stable engagement with compatible implant abutment systems, allowing accurate rotational control and reliable handling during abutment removal, replacement, and prosthetic maintenance procedures.
The ergonomic design supports efficient clinical handling and controlled operation during implant restorative procedures.
Manufactured from medical-grade stainless steel, the instrument provides excellent dimensional precision, corrosion resistance, mechanical durability, and long-term clinical reliability.
Intended Use
The Retrieval Tool Key for Abutment is intended for:
- Implant abutment retrieval procedures
- Prosthetic component removal
- Implant restorative maintenance
- Abutment replacement procedures
- Implant prosthetic applications
- Oral implantology restorative procedures
Indications for Use
The instrument is indicated for use in dental implant restorative procedures requiring controlled engagement, removal, and handling of implant abutments and prosthetic components.
Contraindications
Do not use the instrument:
- For procedures other than intended dental implant applications
- With incompatible implant systems or prosthetic components
- If the instrument is damaged, bent, worn, or corroded
- Without proper sterilization before clinical use
Warnings
- The instrument must be used only by qualified dental professionals trained in implantology procedures.
- Excessive force may damage implant components or prosthetic structures.
- Inspect the instrument before each use for wear, deformation, or damage.
- Ensure proper engagement with the abutment before applying rotational force.
- Use only compatible implant systems and prosthetic components.
Precautions
- Sterilize the instrument before first use and before each subsequent use.
- Avoid excessive mechanical force during retrieval procedures.
- Clean the instrument immediately after use to prevent residue accumulation.
- Follow standard implantology and restorative protocols.
- Use appropriate clinical techniques during prosthetic maintenance procedures.
Directions for Use
1. Clean and sterilize the instrument before use.
2. Verify compatibility between the Retrieval Tool Key and the implant abutment system.
3. Engage the working tip securely with the abutment or prosthetic component.
4. Apply controlled rotational movement to loosen or retrieve the component according to the clinical protocol.
5. Carefully remove the abutment or prosthetic component from the implant system.
6. After completion of the procedure, clean, disinfect, and sterilize the instrument before reuse.
Cleaning and Disinfection
Immediately after use:
- Remove visible debris and biological contaminants.
- Rinse thoroughly under running water.
- Clean manually or using an ultrasonic cleaner with approved medical instrument detergent.
- Dry the instrument completely before sterilization.
Sterilization
- The instrument must be sterilized before use in an autoclave at: 135°C (274°F)
- Sterilization must be performed according to standard dental sterilization procedures and local regulations.
Storage
- Store in a clean, dry environment.
- Protect from moisture and contamination.
- Store in appropriate sterilization packaging until use.
CadCam