Product Description
Titanium Temporary Abutment Round 0.5 for Implant H2.43
The Titanium Temporary Abutment Round 0.5 for Implant H2.43 is a precision prosthetic component designed for the fabrication and support of screw-retained temporary and permanent bridge restorations on implants with an Internal Hex H2.43 connection. The abutment provides a stable prosthetic platform for customized restorations while ensuring excellent fit, strength, and long-term clinical reliability.
Manufactured from high-quality Ti6Al4V medical titanium alloy ASTM F136, the abutment offers exceptional biocompatibility, corrosion resistance, and mechanical strength for implant-supported restorative procedures.
The abutment is supplied in a straight configuration with a prosthetic shoulder and a round prosthetic platform. The design is manufactured without an anti-rotation element, making it particularly suitable for splinted bridge restorations and multi-unit prosthetic applications where passive fit and prosthetic flexibility are required.
The Titanium Temporary Abutment Round 0.5 is intended for both temporary and permanent screw-retained bridge restorations and serves as a reliable platform for laboratory customization and CAD/CAM restorative workflows.
The component connects directly to Internal Hex H2.43 implants and is secured using Titanium Prosthetic Screw (701203).
Specifications
- Product Type: Titanium Temporary Abutment Round 0.5
- Implant Connection: Internal Hex H2.43
- Configuration: Straight
- Prosthetic Platform: Round
- Anti-Rotation Feature: None
- Shoulder Diameter: 4.5 mm
- Shoulder Height: 0.5 mm
- Material: Ti6Al4V Medical Titanium Alloy ASTM F136
- Fixation Screw: Titanium Screw (701203)
- Restoration Type: Screw-retained temporary and permanent bridge restorations
- Sterilization: Fully autoclavable
Compatible Implant Systems
- UNIQUE Implants diameters: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PERFECT Implants Diameters: Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PRIMA Implants Diameters: Ø3.3 mm, Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
Compatible Components
- Titanium Prosthetic Screw (701203)
- Internal Hex H2.43 Implants
- Temporary Bridge Restorations
- Permanent Bridge Restorations
- CAD/CAM Restorations
Indications for Use
Intended for use in the fabrication and fixation of:
- Temporary bridge restorations
- Permanent bridge restorations
- Screw-retained restorations
- Multi-unit restorations
- Implant-supported bridges
- Full-arch restorations
- CAD/CAM restorative procedures
Advantages
- Designed specifically for Internal Hex H2.43 implants
- Round prosthetic platform for bridge restorations
- Straight abutment design with 0.5 mm shoulder
- Suitable for temporary and permanent restorations
- Ideal for splinted and multi-unit restorations
- Supports screw-retained restorative protocols
- Compatible with CAD/CAM and conventional laboratory workflows
- High-strength Ti6Al4V ASTM F136 titanium construction
- Outstanding biocompatibility and corrosion resistance
- Precision-machined restorative interface
- Reliable long-term clinical performance
- Fully autoclavable
Sterilization
Before use, sterilization in an autoclave at a temperature of 135°C (274°F) is required.
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Titanium Temporary Abutment Round 0.5 for Implant H2.43
Intended Use
The Titanium Temporary Abutment Round 0.5 for Implant H2.43 is intended for the fabrication and support of screw-retained temporary and permanent bridge restorations on compatible Internal Hex H2.43 implants.
The abutment serves as a prosthetic interface between the implant and the restoration, providing stability, retention, and accurate positioning of multi-unit and bridge restorations.
The round prosthetic platform without an anti-rotation element is specifically designed for splinted restorations, bridge frameworks, and full-arch prosthetic applications.
Indications
The Titanium Temporary Abutment Round 0.5 for Implant H2.43 is indicated for:
- Temporary bridge restorations
- Permanent bridge restorations
- Screw-retained restorations
- Implant-supported bridges
- Multi-unit restorations
- Full-arch restorations
- CAD/CAM restorations
- Implant rehabilitation procedures
Clinical Procedure
Abutment Installation
1. Confirm successful implant placement or osseointegration according to the treatment protocol.
2. Remove the healing abutment or temporary restoration if present.
3. Clean and inspect the implant connection.
4. Position the Titanium Temporary Abutment Round 0.5 onto the Internal Hex H2.43 implant.
5. Verify complete seating of the abutment.
6. Insert the Titanium Screw (701203).
7. Tighten according to the implant system manufacturer's recommended torque values.
Restoration Fabrication
Laboratory Procedure
1. Verify correct positioning of the abutment on the master model.
2. Design the bridge framework according to the treatment plan.
3. Fabricate the restoration using conventional laboratory techniques or CAD/CAM technology.
4. Verify passive fit of the framework before finalization.
5. Finish and polish the restoration according to laboratory standards.
Temporary Restoration
1. Fabricate a provisional bridge restoration as required.
2. Verify fit, occlusion, and esthetics.
3. Adjust as necessary before delivery.
Restoration Delivery
Screw-Retained Restoration
1. Seat the bridge restoration onto the abutments.
2. Verify complete seating and passive fit.
3. Tighten prosthetic screws according to the recommended torque protocol.
4. Check restoration stability.
5. Verify occlusion and articulation.
6. Seal screw access channels using appropriate restorative materials.
Final Restoration Verification
Before treatment completion:
1. Verify complete seating of all abutments.
2. Confirm passive fit of the bridge framework.
3. Check restoration stability.
4. Verify occlusal contacts.
5. Confirm esthetics and soft tissue adaptation.
6. Obtain radiographic verification if indicated.
Removal Procedure
1. Remove restorative material from the screw access channels.
2. Loosen the prosthetic screws.
3. Remove the bridge restoration carefully.
4. Unscrew and remove the abutments if required.
5. Inspect all components before reuse or replacement.
Cleaning and Sterilization
- Remove all contaminants and manufacturing residues.
- Clean using approved medical device cleaning procedures.
- Rinse thoroughly with distilled or deionized water.
- Dry completely before sterilization.
- Sterilize before use in a steam autoclave at: 135°C (274°F)
- Follow validated sterilization procedures and local regulatory requirements.
Warnings and Precautions
- For professional dental use only.
- Use only with compatible Internal Hex H2.43 implant systems.
- Use only with Titanium Screw (701203).
- Verify complete seating before tightening.
- Follow recommended torque values.
- Do not use damaged or deformed components.
- Replace components showing signs of wear, deformation, or damage.
- Ensure passive fit of bridge restorations before final fixation.
- Intended primarily for splinted and bridge restorations where anti-rotation features are not required.
Storage
Store in a clean, dry environment protected from contamination, moisture, and mechanical damage.
CadCam