Product Description
The Titanium Abutment H2.43 1mm for Immediate Loading is a precision-engineered prosthetic component designed for immediate-loading and cement-retained implant-supported restorations. Manufactured from medical-grade Ti6Al4V ASTM F136 titanium alloy, this abutment provides excellent strength, biocompatibility, and long-term clinical reliability.
Featuring a straight profile with a 1 mm transmucosal shoulder and a 2.43 mm anti-rotational hex connection, the abutment ensures accurate positioning and a stable implant-abutment interface. The shoulder design supports soft tissue management and facilitates the fabrication of cement-retained restorations while maintaining restorative flexibility.
The abutment connects directly to compatible H2.43 implants using fixation screw 701203. Designed for immediate-loading protocols when adequate primary implant stability has been achieved, it provides a reliable foundation for provisional and definitive restorations.
Advantages
- Manufactured from medical-grade Ti6Al4V ASTM F136 titanium alloy.
- Designed for immediate-loading restorative protocols.
- 1 mml transmucosal shoulder supports soft tissue management.
- Anti-rotational 2.43 mm hex connection for precise positioning and stability.
- Suitable for cement-retained implant-supported restorations.
- Excellent mechanical strength and corrosion resistance.
- Bio-compatible material suitable for long-term clinical use.
- Direct connection to H2.43 implant platform.
- Supports provisional and definitive restorative procedures.
- Provides predictable prosthetic outcomes and restoration stability.
Specifications
- Connection: H2.43 Internal Hex 2.43 mm
- Shoulder Diameter: 4.5 mm
- Shoulder Height: 1 mm
- Material: Ti6Al4V ASTM F136 Titanium Alloy
- Fixation Screw: 701203
Compatible Implants
UTI Implants Diameters: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
Indications
- Immediate-loading implant restorations.
- Cement-retained implant-supported restorations.
- Provisional and definitive restorations.
- Single-unit and multiple-unit prosthetic restorations.
Sterilization
The product is supplied non-sterile. Prior to clinical use, sterilization in an autoclave at 135°C (274°F) is required according to validated sterilization procedures.
Reviews
There are no reviews for this product, be the first to leave your review.
Titanium Abutment H2.43 1 mm for Immediate Loading
Intended Use
The Titanium Abutment H2.43 1 mm for Immediate Loading is intended for use with compatible dental implants to support immediate-loading, temporary, and definitive cement-retained implant-supported restorations.
Contraindications
Do not use:
- With implant systems not listed in these instructions.
- If the component is damaged, deformed, or contaminated.
- In patients with conditions that contraindicate implant treatment.
- When compatibility with the implant system cannot be verified.
- When adequate implant primary stability for immediate loading cannot be achieved.
- In cases of failed osseointegration or implant instability.
Warnings
- This product is intended for use only by qualified dental professionals.
- Immediate loading should only be performed when sufficient primary implant stability has been achieved according to accepted clinical protocols.
- Use only original compatible components and fixation screws.
- Failure to properly seat the abutment may result in mechanical complications, component loosening, or restoration failure.
- Excessive occlusal loading during the healing phase may compromise osseointegration and treatment outcomes.
- The product is intended for single-patient use only.
Precautions
- Verify implant compatibility before use.
- Inspect the abutment and fixation screw prior to use.
- Confirm complete seating of the abutment before tightening the fixation screw.
- Verify proper fit clinically and radiographically.
- Minimize occlusal contacts and lateral loading during the immediate-loading phase.
- Follow accepted clinical protocols for implant restoration and maintenance.
- Maintain traceability of the product lot number in patient records.
Instructions for Use
Clinical Procedure
1. Verify compatibility of the abutment with the selected implant system.
2. Confirm that adequate primary implant stability has been achieved for immediate loading.
3. Remove the healing component or cover screw and clean the implant connection.
4. Seat the Titanium Abutment H2.43 1 mm for Immediate Loading into the implant connection and verify complete seating.
5. Secure the abutment using fixation screw 701203 and tighten according to the implant system protocol.
6. Verify the position and fit of the abutment clinically and radiographically.
7. Fabricate or place the provisional or definitive cement-retained restoration.
8. Verify occlusion, stability, and soft tissue adaptation.
9. Adjust the restoration to minimize excessive occlusal forces during the healing period.
10. Remove all excess cement.
11. Perform routine follow-up examinations according to accepted clinical protocols.
Sterilization
- The product is supplied non-sterile.
- Before clinical use, clean and sterilize the abutment using a validated steam sterilization cycle. Autoclave sterilization at 135°C (274°F) is required prior to placement.
- Do not use the product if sterility cannot be assured.
Storage
Store in a clean, dry environment in the original packaging. Protect from contamination, excessive heat, direct sunlight, moisture, and mechanical damage.
CadCam