Product Description
Universal Hex Driver 1.27 mm for Open Cover Screw
The Universal Hex Driver 1.27 mm for Open Cover Screw is a precision surgical instrument designed for the placement and removal of open cover screws used in dental implant procedures. Manufactured from high-quality surgical stainless steel, the instrument provides excellent durability, corrosion resistance, and reliable performance in clinical applications.
The driver features a hollow 1.27 mm hexagonal tip specifically designed to engage compatible open cover screws securely, allowing clinicians to tighten and loosen components with accuracy and control. Its hollow design facilitates access to implant components in confined surgical areas and ensures efficient handling during second-stage implant procedures.
The Universal Hex Driver is commonly used during implant uncovering procedures and is frequently utilized in conjunction with the DMi Gingival Perforator (471230) when exposing osseointegrated implants during the second surgical stage.
Designed for repeated clinical use, the instrument can be cleaned, sterilized, and reused according to standard surgical protocols.
Advantages
- Precision 1.27 mm hex engagement.
- Designed specifically for open cover screw placement and removal.
- Hollow driver design improves accessibility and handling.
- Manufactured from high-quality surgical stainless steel.
- Excellent corrosion resistance and durability.
- Suitable for second-stage implant surgery.
- Frequently used in conjunction with gingival perforators.
- Provides secure screw engagement and torque transfer.
- Reusable following proper cleaning and sterilization procedures.
Specifications
- Product Type: Universal Hex Driver
- Hex Size: 1.27 mm
- Design: Hollow Hex Driver
- Material: Surgical Stainless Steel
- Reusable: Yes
- Sterilization: Steam Autoclave
Indications
- Tightening open cover screws.
- Loosening open cover screws.
- Second-stage implant surgery.
- Implant uncovering procedures.
- Exposure of osseointegrated implants.
- Use with compatible implant systems and surgical instruments.
Compatible Components
- Open Cover Screws
- Gingival Perforator (471230)
- Compatible implant systems utilizing 1.27 mm hex open cover screws
Sterilization
- The product is supplied non-sterile.
- Before each clinical use, clean and sterilize the instrument using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage.
The Universal Hex Driver 1.27 mm for Open Cover Screw is a precision surgical instrument designed for the placement and removal of open cover screws used in dental implant procedures. Manufactured from high-quality surgical stainless steel, the instrument provides excellent durability, corrosion resistance, and reliable performance in clinical applications.
The driver features a hollow 1.27 mm hexagonal tip specifically designed to engage compatible open cover screws securely, allowing clinicians to tighten and loosen components with accuracy and control. Its hollow design facilitates access to implant components in confined surgical areas and ensures efficient handling during second-stage implant procedures.
The Universal Hex Driver is commonly used during implant uncovering procedures and is frequently utilized in conjunction with the DMi Gingival Perforator (471230) when exposing osseointegrated implants during the second surgical stage.
Designed for repeated clinical use, the instrument can be cleaned, sterilized, and reused according to standard surgical protocols.
Advantages
- Precision 1.27 mm hex engagement.
- Designed specifically for open cover screw placement and removal.
- Hollow driver design improves accessibility and handling.
- Manufactured from high-quality surgical stainless steel.
- Excellent corrosion resistance and durability.
- Suitable for second-stage implant surgery.
- Frequently used in conjunction with gingival perforators.
- Provides secure screw engagement and torque transfer.
- Reusable following proper cleaning and sterilization procedures.
Specifications
- Product Type: Universal Hex Driver
- Hex Size: 1.27 mm
- Design: Hollow Hex Driver
- Material: Surgical Stainless Steel
- Reusable: Yes
- Sterilization: Steam Autoclave
Indications
- Tightening open cover screws.
- Loosening open cover screws.
- Second-stage implant surgery.
- Implant uncovering procedures.
- Exposure of osseointegrated implants.
- Use with compatible implant systems and surgical instruments.
Compatible Components
- Open Cover Screws
- Gingival Perforator (471230)
- Compatible implant systems utilizing 1.27 mm hex open cover screws
Sterilization
- The product is supplied non-sterile.
- Before each clinical use, clean and sterilize the instrument using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage.
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
INSTRUCTION FOR USE
Universal Hex Driver 1.27 mm for Open Cover Screw
Intended Use
The Universal Hex Driver 1.27 mm for Open Cover Screw is intended for the installation and removal of open cover screws used during modified two-stage dental implant procedures. The instrument is specifically designed to engage the 1.25 mm hex connection of compatible open cover screws and facilitate implant uncovering procedures during the second surgical stage.
Indications
- Installation of open cover screws.
- Removal of open cover screws.
- Modified two-stage implant protocols.
- Implant uncovering procedures.
- Exposure of osseointegrated implants.
- Use in conjunction with a gingival perforator during the second surgical stage.
Contraindications
Do not use:
- For applications other than those specified in these instructions.
- If the instrument is damaged, worn, bent, or corroded.
- With incompatible implant systems or screw designs.
- If secure engagement between the driver and screw cannot be achieved.
Warnings
- This product is intended for use only by qualified dental professionals and oral surgeons.
- Verify complete engagement of the driver within the screw hex connection before applying torque.
- Excessive tightening force may damage the screw or implant connection.
- Maintain sterility throughout the procedure.
- Inspect the instrument before each use.
Precautions
- Use only with compatible open cover screws featuring a 1.25 mm hex connection.
- Confirm implant stability and osseointegration before beginning the second surgical stage.
- Apply only light tightening torque when installing the open cover screw.
- Follow the implant manufacturer's recommended clinical protocol.
Clinical Procedure
Stage 1 – Installation of Open Cover Screw
1. Verify that the implant has been placed according to the surgical protocol.
2. Select the appropriate open cover screw (720838 or compatible equivalent).
3. Ensure that the screw and driver have been properly cleaned and sterilized.
4. Engage the Universal Hex Driver 1.27 mm with the 1.25 mm hex connection of the open cover screw.
5. Insert the screw into the internal connection of the implant.
6. Tighten the screw gently until fully seated.
7. Verify proper positioning of the protruding pin above the implant platform.
8. Perform complete soft tissue closure over the implant and open cover screw.
9. Allow healing according to the prescribed treatment protocol.
Stage 2 – Implant Uncovering Procedure
1. Confirm successful osseointegration of the implant.
2. Locate the position of the open cover screw pin by palpation through the soft tissue.
3. Position the Gingival Perforator (471230) directly above the screw pin.
4. Engage the Universal Hex Driver 1.27 mm through the gingival perforator.
5. Engage the hex connection of the open cover screw.
6. Remove the screw while simultaneously removing the soft tissue core above the implant.
7. Remove the gingival perforator and extracted tissue.
8. Verify complete exposure of the implant connection.
9. Proceed with restorative procedures as clinically indicated.
Prosthetic Phase
Following removal of the open cover screw and exposure of the implant platform, prosthetic treatment may begin immediately according to the implant system protocol.
Cleaning and Sterilization
- Thoroughly clean the instrument to remove blood, tissue residues, and contaminants.
- Pay particular attention to the hollow hex connection.
- Rinse thoroughly with clean water.
- Dry completely before sterilization.
- Sterilize using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
- Do not use the instrument if sterility cannot be assured.
Maintenance
- Inspect the hex engagement surfaces regularly.
- Replace the instrument if wear, deformation, corrosion, or damage is observed.
- Do not modify the instrument.
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage.
Intended Use
The Universal Hex Driver 1.27 mm for Open Cover Screw is intended for the installation and removal of open cover screws used during modified two-stage dental implant procedures. The instrument is specifically designed to engage the 1.25 mm hex connection of compatible open cover screws and facilitate implant uncovering procedures during the second surgical stage.
Indications
- Installation of open cover screws.
- Removal of open cover screws.
- Modified two-stage implant protocols.
- Implant uncovering procedures.
- Exposure of osseointegrated implants.
- Use in conjunction with a gingival perforator during the second surgical stage.
Contraindications
Do not use:
- For applications other than those specified in these instructions.
- If the instrument is damaged, worn, bent, or corroded.
- With incompatible implant systems or screw designs.
- If secure engagement between the driver and screw cannot be achieved.
Warnings
- This product is intended for use only by qualified dental professionals and oral surgeons.
- Verify complete engagement of the driver within the screw hex connection before applying torque.
- Excessive tightening force may damage the screw or implant connection.
- Maintain sterility throughout the procedure.
- Inspect the instrument before each use.
Precautions
- Use only with compatible open cover screws featuring a 1.25 mm hex connection.
- Confirm implant stability and osseointegration before beginning the second surgical stage.
- Apply only light tightening torque when installing the open cover screw.
- Follow the implant manufacturer's recommended clinical protocol.
Clinical Procedure
Stage 1 – Installation of Open Cover Screw
1. Verify that the implant has been placed according to the surgical protocol.
2. Select the appropriate open cover screw (720838 or compatible equivalent).
3. Ensure that the screw and driver have been properly cleaned and sterilized.
4. Engage the Universal Hex Driver 1.27 mm with the 1.25 mm hex connection of the open cover screw.
5. Insert the screw into the internal connection of the implant.
6. Tighten the screw gently until fully seated.
7. Verify proper positioning of the protruding pin above the implant platform.
8. Perform complete soft tissue closure over the implant and open cover screw.
9. Allow healing according to the prescribed treatment protocol.
Stage 2 – Implant Uncovering Procedure
1. Confirm successful osseointegration of the implant.
2. Locate the position of the open cover screw pin by palpation through the soft tissue.
3. Position the Gingival Perforator (471230) directly above the screw pin.
4. Engage the Universal Hex Driver 1.27 mm through the gingival perforator.
5. Engage the hex connection of the open cover screw.
6. Remove the screw while simultaneously removing the soft tissue core above the implant.
7. Remove the gingival perforator and extracted tissue.
8. Verify complete exposure of the implant connection.
9. Proceed with restorative procedures as clinically indicated.
Prosthetic Phase
Following removal of the open cover screw and exposure of the implant platform, prosthetic treatment may begin immediately according to the implant system protocol.
Cleaning and Sterilization
- Thoroughly clean the instrument to remove blood, tissue residues, and contaminants.
- Pay particular attention to the hollow hex connection.
- Rinse thoroughly with clean water.
- Dry completely before sterilization.
- Sterilize using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
- Do not use the instrument if sterility cannot be assured.
Maintenance
- Inspect the hex engagement surfaces regularly.
- Replace the instrument if wear, deformation, corrosion, or damage is observed.
- Do not modify the instrument.
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage.
Universal Hex Driver 1.27mmd for Open Cover Screw