Product Description
The Motor Hex 2.43 Implant Drive Key for Contra Angle is a precision implantology instrument designed for machine-driven insertion and removal of dental implants and implant components during oral implant surgery and restorative procedures. The instrument is intended for use with implant systems featuring H2.43 hex socket or CH2.43 conical connection interfaces and is specifically engineered for controlled motor-driven clinical applications.
The driver features a precision-machined 2.43 mm hex working tip that provides secure engagement with compatible implant systems, allowing accurate torque transfer and stable implant handling during placement and removal procedures.
The working section of the instrument has a length of 12 mm, providing controlled surgical access and precise implant manipulation during implant placement procedures. The driver includes high guiding edges that assist in visual orientation of the implant hex position, supporting accurate implant alignment and prosthetic positioning.
The instrument contains two reference markings indicating implant immersion depth and gingival penetration levels at 3 mm and 5 mm, allowing improved visualization and controlled implant placement during surgery.
The upper section of the instrument is designed for secure attachment to a contra-angle handpiece or physiodispenser system, ensuring stable rotational performance and controlled surgical operation.
Manufactured from high-quality medical-grade 420 stainless steel, the instrument provides excellent dimensional precision, corrosion resistance, mechanical durability, and long-term clinical reliability. The smooth polished surface supports effective cleaning and sterilization procedures.
Suitable for:
- Machine-driven implant insertion
- Implant removal procedures
- Surgical implant placement
- Implant positioning procedures
- Oral implantology surgery
- Implant restorative applications
The precision 2.43 mm hex connection allows stable implant engagement and reliable torque transmission during implant placement and removal procedures.
Specifications
- Instrument type: Motor implant drive key
- Hex size: 2.43 mm
- Working length: 12 mm
- Connection type: H2.43 / CH2.43 compatible
- Handpiece connection: Contra angle
- Depth markings: 3 mm and 5 mm reference indicators
- Material: Medical-grade 420 stainless steel
- Surface finish: Smooth polished surface
- Application: Motor-driven implant procedures
- Sterilization: Fully autoclavable
Indications for Use
Intended for:
- Implant insertion procedures
- Implant removal procedures
- Surgical implant placement
- Implant positioning during surgery
- Oral implantology applications
- Controlled implant torque procedures
Sterilization
The instrument must be sterilized before use in an autoclave at: 135°C (274°F)
Advantages
- Precision 2.43 mm hex connection
- Compatible with H2.43 and CH2.43 implant systems
- Accurate torque transmission
- Stable implant engagement
- 12 mm working length for controlled access
- High guiding edges for implant orientation
- 3 mm and 5 mm depth reference markings
- Designed for contra-angle handpieces
- High-strength 420 stainless steel construction
- Excellent corrosion resistance
- Smooth easy-to-clean surface
- Fully autoclavable
- Reliable clinical performance
- Designed for predictable implant placement procedures
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Motor Hex 2.43 Implant Drive Key for Contra Angle
Product Description
The Motor Hex 2.43 Implant Drive Key for Contra Angle is a reusable dental implant instrument intended for machine-driven insertion and removal of dental implants and implant components during oral implant surgery and restorative procedures.
The instrument features a precision-machined 2.43 mm hex working tip designed for secure engagement with compatible implant systems, allowing controlled torque transfer and stable implant handling during clinical procedures.
The working section has a length of 12 mm and includes depth reference markings at 3 mm and 5 mm to assist with implant positioning and depth control during surgical placement.
The upper section of the instrument is designed for secure connection to a contra-angle handpiece or physiodispenser system, providing stable rotational performance and controlled clinical operation.
Manufactured from medical-grade 420 stainless steel, the instrument provides excellent dimensional precision, corrosion resistance, mechanical durability, and long-term clinical reliability.
Intended Use
The Motor Hex 2.43 Implant Drive Key for Contra Angle is intended for:
- Machine-driven implant insertion
- Implant removal procedures
- Surgical implant placement
- Implant positioning procedures
- Oral implantology applications
- Controlled implant torque procedures
Indications for Use
The instrument is indicated for use in dental implant surgical and restorative procedures requiring controlled insertion or removal of implants compatible with H2.43 hex socket or CH2.43 conical connection systems.
Contraindications
Do not use the instrument:
- For procedures other than intended dental implant applications
- With incompatible implant systems or incorrect hex connections
- If the instrument is damaged, bent, worn, or corroded
- Without proper sterilization before clinical use
Warnings
- The instrument must be used only by qualified dental professionals trained in implantology procedures.
- Always verify proper engagement between the driver and implant before operation.
- Excessive torque or improper use may damage the implant or instrument.
- Inspect the instrument before each use for wear, deformation, or damage.
- Use only compatible contra-angle handpieces and implant systems.
Precautions
- Sterilize the instrument before first use and before each subsequent use.
- Avoid excessive mechanical force during implant placement or removal.
- Clean the instrument immediately after use to prevent residue accumulation.
- Follow standard implant surgical protocols and manufacturer recommendations.
- Use appropriate irrigation and clinical operating procedures when necessary.
Directions for Use
1. Clean and sterilize the instrument before use.
2. Attach the Motor Hex 2.43 Implant Drive Key securely to a compatible contra-angle handpiece or physiodispenser.
3. Verify proper connection and rotational stability.
4. Engage the 2.43 mm hex tip with the implant connection or implant carrier.
5. Position the implant according to the surgical protocol.
6. Use the 3 mm and 5 mm depth reference markings to monitor implant placement depth.
7. Operate the handpiece according to the implant system protocol.
8. After completion of the procedure, carefully remove the instrument.
9. Clean, disinfect, and sterilize the instrument before reuse.
Cleaning and Disinfection
Immediately after use:
- Remove visible debris and contaminants.
- Rinse thoroughly under running water.
- Clean manually or using an ultrasonic cleaner with approved medical instrument detergent.
- Dry the instrument completely before sterilization.
Sterilization
- The instrument must be sterilized before use in an autoclave at: 135°C (274°F)
- Sterilization must be performed according to standard dental sterilization procedures and local regulations.
Storage
- Store in a clean, dry environment.
- Protect from moisture and contamination.
- Store in appropriate sterilization packaging until use.
CadCam