Product Description
Universal Hex Driver Key 1.77 mm
The Universal Hex Driver Key 1.77 mm is a precision surgical and prosthetic instrument designed for the installation and removal of implant screws, prosthetic components, and restorative accessories requiring a 1.77 mm hex connection. Manufactured from high-quality surgical stainless steel, the driver provides exceptional durability, corrosion resistance, and reliable torque transfer during clinical procedures.
The instrument features a precision-machined 1.77 mm hex tip for secure engagement with compatible implant components. Its ergonomic body design provides excellent grip and handling, allowing clinicians to achieve accurate component placement and controlled tightening or loosening of prosthetic screws.
The Universal Hex Driver Key is suitable for both surgical and restorative implant procedures and may be used manually or in conjunction with compatible surgical ratchets, hand drivers, and torque instruments depending on the clinical application.
Designed for repeated clinical use, the instrument can be cleaned, sterilized, and reused according to established protocols.
Advantages
- Precision 1.77 mm hex connection.
- Secure engagement with compatible implant components.
- Excellent torque transmission and control.
- Manufactured from high-quality surgical stainless steel.
- Corrosion-resistant and durable construction.
- Ergonomic design for comfortable handling.
- Suitable for surgical and prosthetic implant procedures.
- Reusable following proper cleaning and sterilization.
- Compatible with manual and torque-assisted applications.
Specifications
- Product Type: Universal Hex Driver Key
- Hex Size: 1.77 mm
- Material: Surgical Stainless Steel
- Application: Surgical and Prosthetic Implant Procedures
- Reusable: Yes
- Sterilization: Steam Autoclave
Indications
- Tightening prosthetic screws.
- Loosening prosthetic screws.
- Placement of implant restorative components.
- Implant prosthetic procedures.
- Maintenance and servicing of implant restorations.
- Surgical and restorative implant applications.
Compatible Components
- Prosthetic fixation screws.
- Implant abutment screws.
- Restorative implant components requiring a 1.77 mm hex driver.
- Compatible implant system accessories.
Sterilization
- The product is supplied non-sterile.
- Before each clinical use, clean and sterilize the instrument using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage.
Reviews
There are no reviews for this product, be the first to leave your review.
Universal Hex Driver Key 1.77 mm
Intended Use
The Universal Hex Driver Key 1.77 mm is intended for the installation, tightening, loosening, and removal of prosthetic screws, abutment screws, and compatible implant components featuring a 1.77 mm hexagonal connection.
The instrument is designed for use during prosthetic and restorative implant procedures and provides secure engagement and controlled torque transmission to implant-supported restorations.
Indications
- Placement of prosthetic fixation screws.
- Removal of prosthetic fixation screws.
- Installation of implant abutments.
- Removal of implant abutments.
- Maintenance and servicing of implant-supported restorations.
- Single-unit and multiple-unit implant restorations.
- Laboratory and clinical implant prosthetic procedures.
Contraindications
Do not use:
- For applications other than intended implant and prosthetic procedures.
- If the instrument is damaged, bent, worn, or corroded.
- With incompatible implant systems or components.
- If secure engagement with the screw or component cannot be achieved.
Warnings
- This product is intended for use only by qualified dental professionals.
- Verify complete engagement between the driver and the prosthetic screw before applying torque.
- Excessive force may damage the screw, abutment, implant connection, or instrument.
- Inspect the instrument before each use.
- Replace worn or damaged drivers immediately.
Precautions
- Confirm compatibility with the implant system and prosthetic components before use.
- Apply only the torque values recommended by the implant manufacturer.
- Avoid excessive lateral forces during tightening or loosening procedures.
- Maintain sterility throughout the clinical procedure.
- Ensure complete seating of the driver within the screw head before applying torque.
Instructions for Use
Pre-Operative Procedure
1. Inspect the Universal Hex Driver Key for cleanliness, wear, deformation, or damage.
2. Verify compatibility with the implant system and prosthetic component.
3. Clean and sterilize the instrument before use.
4. Ensure that the prosthetic component and fixation screw are free of debris.
Prosthetic Component Installation
1. Engage the 1.77 mm hex tip securely into the prosthetic screw.
2. Insert the screw into the abutment or restoration according to the manufacturer's protocol.
3. Tighten the screw manually until initial seating is achieved.
4. If required, connect the driver to a compatible torque wrench or ratchet.
5. Tighten the screw to the recommended torque value specified by the implant manufacturer.
6. Verify complete seating and stability of the restoration.
Prosthetic Component Removal
1. Engage the 1.77 mm hex tip fully into the screw head.
2. Apply controlled counterclockwise rotation.
3. Remove the screw and component carefully.
4. Inspect the screw and restoration for wear or damage before reinstallation.
Cleaning and Sterilization
- Thoroughly clean the instrument to remove blood, saliva, tissue residues, and contaminants.
- Rinse with clean water.
- Dry completely before sterilization.
- Sterilize using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
- Do not use the instrument if sterility cannot be assured.
Maintenance
- Inspect the 1.77 mm hex tip regularly for wear.
- Replace the instrument if deformation, rounding of the hex tip, corrosion, or damage is observed.
- Do not modify the instrument.
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage. Keep the instrument in a protective surgical tray or instrument cassette when not in use.