Product Description
The Titanium Base for Short Implant H2.43 is a precision prosthetic component designed for the fabrication and fixation of custom zirconia abutments and crowns on short dental implants with an Internal Hex H2.43 connection. The titanium base provides a stable and durable interface between the implant and the prosthetic restoration, ensuring excellent mechanical stability, precise fit, and long-term clinical performance.
Manufactured from high-quality Ti6Al4V medical titanium alloy ASTM F136, the titanium base offers exceptional biocompatibility, corrosion resistance, mechanical strength, and predictable restorative outcomes.
The component is specifically designed for screw-retained and cement-retained permanent restorations on osseointegrated short implants. The titanium base serves as a prosthetic platform for the fabrication of custom zirconia abutments and crowns and supports both conventional laboratory and CAD/CAM restorative workflows.
The titanium base is supplied in a straight configuration with a shoulder and incorporates an anti-rotation feature between the titanium base and the implant, as well as an anti-rotation feature between the titanium base and the prosthetic restoration. These features provide enhanced stability and accurate positioning of the final restoration.
The component connects directly to compatible Internal Hex H2.43 short implant systems and is secured using Titanium Prosthetic Screw (701207).
Specifications
- Product Type: Titanium Base for Short Implant
- Implant Connection: Internal Hex H2.43
- Shoulder Diameter: 4.5 mm
- Body Height: 4.0 mm
- Design: Straight with shoulder
- Anti-Rotation Feature: Yes
- Material: Ti6Al4V Medical Titanium Alloy ASTM F136
- Fixation Screw: Titanium Screw (701207)
- Restoration Type: Screw-retained and cement-retained permanent restorations
- Sterilization: Fully autoclavable
Compatible Implant Systems
- UNIQUE Short Implants Diameters: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm and Lengths: 5 mm, 6 mm, 7 mm.
- PRIMA Short Implants Diameters: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm and Lengths: 5 mm, 6 mm, 7 mm.
Compatible Components
- Titanium Prosthetic Screw (701207)
- Internal Hex H2.43 Short Implants
- Custom Zirconia Abutments
- Custom Zirconia Crowns
- CAD/CAM Restorations
Indications for Use
Intended for use in the fabrication and fixation of:
- Custom zirconia abutments
- Custom zirconia crowns
- Screw-retained restorations
- Cement-retained restorations
- Single-tooth restorations
- Implant-supported prosthetic restorations
- Permanent implant restorations
- CAD/CAM restorative procedures
Advantages
- Designed specifically for Internal Hex H2.43 short implants
- Suitable for custom zirconia abutments and crowns
- Anti-rotation design for enhanced prosthetic stability
- Direct connection to H2.43 implant systems
- Supports screw-retained and cement-retained restorations
- Compatible with CAD/CAM and conventional workflows
- High-strength Ti6Al4V ASTM F136 titanium construction
- Excellent biocompatibility
- Outstanding corrosion resistance
- Precision-machined restorative interface
- Reliable long-term prosthetic performance
- Fully autoclavable
Sterilization
Before use, sterilization in an autoclave at a temperature of 135°C (274°F) is required.
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Titanium Base for Short Implant H2.43
Intended Use
The Titanium Base for Short Implant H2.43 is intended for the fabrication and fixation of custom zirconia abutments and crowns on compatible Internal Hex H2.43 short implants. The component serves as a prosthetic interface between the implant and the definitive restoration, providing stable support for long-term implant-supported prosthetic rehabilitation.
The titanium base is designed for both screw-retained and cement-retained permanent restorations and is suitable for single-tooth restorations and implant-supported prosthetic applications.
Indications
The Titanium Base for Short Implant H2.43 is indicated for:
- Custom zirconia abutments
- Custom zirconia crowns
- Screw-retained restorations
- Cement-retained restorations
- Single-tooth restorations
- Permanent implant restorations
- CAD/CAM restorations
- Implant rehabilitation procedures
Laboratory Procedure
Restoration Fabrication
1. Verify compatibility of the Titanium Base with the H2.43 implant platform.
2. Inspect the component for cleanliness and integrity.
3. Design the custom zirconia abutment or crown according to the treatment plan.
4. Fabricate the restoration using conventional laboratory techniques or CAD/CAM technology.
5. Bond or secure the zirconia restoration to the titanium base according to the selected restorative protocol.
6. Verify passive fit, proper alignment, and emergence profile before clinical delivery.
Clinical Procedure
Titanium Base Installation
1. Confirm successful osseointegration of the implant.
2. Clean and inspect the implant connection.
3. Position the Titanium Base onto the Internal Hex H2.43 implant platform.
4. Verify engagement of the anti-rotation feature.
5. Ensure complete seating of the titanium base.
Restoration Fixation
For Screw-Retained Restorations
1. Seat the completed zirconia restoration onto the implant.
2. Insert the Titanium Screw (701207).
3. Tighten the screw according to the implant system manufacturer's recommended torque values.
4. Verify complete seating and stability of the restoration.
5. Check occlusion and adjust if necessary.
6. Seal the screw access channel according to the restorative protocol.
For Cement-Retained Restorations
1. Verify complete seating of the titanium base.
2. Cement the custom zirconia restoration onto the titanium base according to the cement manufacturer's instructions.
3. Remove excess cement carefully.
4. Verify occlusion and final restoration fit.
Final Restoration Verification
Before completion of treatment:
1. Verify passive fit of the restoration.
2. Confirm complete seating of the titanium base.
3. Verify anti-rotation engagement.
4. Check restoration stability.
5. Verify proper occlusal contacts.
6. Confirm esthetics and soft tissue adaptation.
Removal Procedure
Screw-Retained Restoration
1. Remove restorative material from the screw access channel.
2. Loosen the Titanium Screw (701207) using the appropriate driver.
3. Remove the restoration carefully.
4. Inspect all components before reuse or replacement.
Cement-Retained Restoration
1. Remove the prosthetic restoration according to the clinical protocol.
2. Inspect the titanium base and implant connection.
3. Replace damaged components if necessary.
Cleaning and Sterilization
- Remove all contaminants and manufacturing residues.
- Clean using approved medical device cleaning procedures.
- Rinse thoroughly with distilled or deionized water.
- Dry completely before sterilization.
- Sterilize before use in a steam autoclave at: 135°C (274°F)
- Follow validated sterilization procedures and local regulatory requirements.
Warnings and Precautions
- For professional dental use only.
- Use only with compatible Internal Hex H2.43 short implant systems.
- Use only with Titanium Screw (701207).
- Verify engagement of anti-rotation features before final tightening.
- Follow recommended torque values.
- Do not use damaged or deformed components.
- Components showing signs of wear, deformation, or damage must be replaced.
- Ensure passive fit of the restoration before final fixation.
Storage
Store in a clean, dry environment protected from contamination, moisture, and mechanical damage.
CadCam