Product Description
The Angular Titanium Abutment H2.43 for Turning 15° is designed for the fabrication of custom cement-retained implant restorations. Featuring a 15° angled body relative to the implant axis, it enables correction of implant angulation and facilitates optimal prosthetic positioning in challenging clinical situations.
Manufactured from high-strength medical-grade titanium alloy (Ti6Al4V) in accordance with ASTM F136 standards, the abutment provides excellent biocompatibility, durability, and precision for custom prosthetic fabrication. It is intended for use with implants featuring an internal hex connection of 2.43 mm and an internal thread of 1-72 UNF. The abutment connects directly to the implant using fixation screw 701203.
This component is supplied as a prefabricated titanium base for dental laboratory use and is designed to be customized by milling and turning to create a patient-specific implant abutment.
Compatible Implant Systems
- UNIQUE Implants: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PERFECT Implants: Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PRIMA Implants: Ø3.3 mm, Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
Key Features
- Designed for cement-retained restorations
- 15° angled abutment body
- Internal hex connection: H2.43 mm
- Internal thread: 1-72 UNF
- Manufactured from Ti6Al4V ASTM F136 medical-grade titanium
- Suitable for custom milling and turning procedures
- Direct implant connection with screw 701203
- Intended for dental laboratory applications
Sterilization
Prior to clinical use, the abutment must be sterilized in an autoclave at 135°C (275°F) according to standard sterilization protocols.
Reviews
There are no reviews for this product, be the first to leave your review.
Angular Titanium Abutment H2.43 for Turning 15°
Intended Use
The Angular Titanium Abutment H2.43 for Turning 15° is intended for the fabrication of custom implant-supported cement-retained restorations. The component is customized by milling and turning procedures performed in a dental laboratory.
Contraindications
Do not use:
- In patients with known allergy or hypersensitivity to titanium alloys.
- With implant systems not listed in these instructions.
- If the component is damaged or shows signs of deformation or contamination.
Warnings
- This product is intended for use only by qualified dental professionals and dental laboratories.
- Use only original compatible components.
- Improper use may result in prosthetic complications, loosening of components, or restoration failure.
- Do not modify the implant connection interface.
Precautions
- Verify compatibility before use.
- Inspect the component prior to use.
- Avoid excessive material removal during milling and customization procedures.
- Follow accepted prosthetic and laboratory protocols.
- Maintain traceability of the product lot number in patient records.
Instructions for Use
Laboratory Procedure
- Verify compatibility of the abutment with the selected implant system.
- Inspect the abutment for damage or defects.
- Customize the abutment by milling and turning according to the planned restoration design.
- Finish and polish the customized abutment following standard laboratory procedures.
- Clean the component thoroughly before sterilization.
Clinical Procedure
- Sterilize the abutment before clinical use.
- Connect the abutment to the implant using fixation screw 701203.
- Verify proper seating and fit of the abutment.
- Fabricate or seat the cement-retained restoration.
- Remove excess cement according to accepted clinical protocols.
- Verify occlusion, stability, and soft tissue adaptation.
Sterilization
- The product is supplied non-sterile.
- Before clinical use, sterilize the abutment in a steam autoclave using a validated sterilization cycle.
- Recommended sterilization temperature: 135°C (275°F)
- Follow the autoclave manufacturer's instructions regarding exposure and drying times.
Storage
Store in a clean, dry environment in the original packaging. Protect from contamination, moisture, and mechanical damage.
CadCam