Product Description
The Titanium Standard Connector 2 mm for Angular Adapter is a precision prosthetic component designed for screw-retained implant restorations utilizing two-piece angular adapter systems. The connector provides a stable prosthetic interface between the angular adapter and the restorative structure, enabling accurate positioning and long-term fixation of implant-supported restorations.
Manufactured from high-quality Ti6Al4V medical titanium alloy ASTM F136, the connector offers exceptional biocompatibility, mechanical strength, corrosion resistance, and long-term clinical reliability.
The component features an M3.5 UNF thread and is designed without an anti-rotation element, allowing direct connection to the Angular Adapter (630141, etc.) through engagement with the internal thread of the adapter.
The connector is intended for use in permanent screw-retained restorations on fully osseointegrated implants and provides a secure prosthetic platform for fixed implant-supported restorations.
The Titanium Standard Connector is used in combination with:
- Angular Adapter (630141, etc.)
- Plastic Sheath (687030)
- Titanium Base (690760, etc.)
- Titanium Prosthetic Screw (700229)
The component is compatible with all two-piece angular adapter systems (630141, etc.), making it suitable for a wide range of implant prosthetic applications.
Suitable for:
- Screw-retained restorations
- Full-arch implant restorations
- Implant-supported bridges
- Multi-unit prosthetic restorations
- Angular correction prosthetic solutions
- Fixed implant restorations
- Oral implantology applications
Specifications
- Product type: Titanium standard connector for angular adapter
- Diameter: 4.0 mm
- Height: 2.0 mm
- Thread type: M3.5 UNF
- Anti-rotation feature: None
- Material: Ti6Al4V medical titanium alloy ASTM F136
- Connection type: Direct connection to angular adapter
- Restoration type: Screw-retained restorations
- Sterilization: Fully autoclavable
Compatible Components
- Angular Adapter (630141, etc.)
- Plastic Sheath (687030)
- Titanium Base (690760, etc.)
- Titanium Prosthetic Screw (700229)
- Two-Piece Angular Adapter Systems (630141, etc.)
- 1.25 mm Hex Driver
Indications for Use
Intended for use in the fabrication and fixation of implant-supported restorations during:
- Full-arch restorations
- Screw-retained prosthetic restorations
- Implant-supported bridges
- Fixed prosthetic rehabilitations
- Angular correction restorations
- Implant restorative procedures
Sterilization
The component must be sterilized before use in an autoclave at: 135°C (274°F)
Advantages
- Precision prosthetic interface for angular adapters
- Compatible with all two-piece angular adapter systems
- M3.5 UNF threaded connection
- Designed for permanent screw-retained restorations
- Direct connection to angular adapter components
- Compatible with plastic sheaths and titanium bases
- High-strength Ti6Al4V ASTM F136 titanium construction
- Excellent bio-compatibility
- Outstanding corrosion resistance
- Precise fit and prosthetic stability
- Fully autoclave
- Designed for predictable long-term implant prosthetic outcomes
Reviews
There are no reviews for this product, be the first to leave your review.
Titanium Standard Connector 2 mm for Angular Adapter
Intended Use
The Titanium Standard Connector 2 mm for Angular Adapter is intended for use as a prosthetic connection component in screw-retained implant restorations supported by two-piece angular adapter systems. The connector provides a secure interface between the angular adapter and the prosthetic restoration, facilitating accurate positioning and long-term fixation of implant-supported prostheses.
The component is designed for permanent restorations on fully osseointegrated dental implants.
Indications
The Titanium Standard Connector 2 mm is indicated for:
- Screw-retained implant restorations
- Full-arch implant rehabilitations
- Implant-supported bridges
- Fixed prosthetic restorations
- Angular correction restorations
- Multi-unit implant prosthetics
- CAD/CAM prosthetic frameworks
Compatible Components
The connector is intended for use with:
- Angular Adapter (630141, etc.)
- Plastic Sheath (687030)
- Titanium Base (690760, etc.)
- Titanium Prosthetic Screw (700229)
- Two-Piece Angular Adapter Systems (630141, etc.)
- 1.25 mm Hex Driver
Product Specifications
- Diameter: 4.0 mm
- Height: 2.0 mm
- Thread Type: M3.5 UNF
- Anti-Rotation Feature: None
- Material: Ti6Al4V Medical Titanium Alloy ASTM F136
Clinical Use
Prosthetic Preparation
- Verify compatibility of all prosthetic components.
- Inspect the Titanium Standard Connector for cleanliness and integrity.
- Confirm that the angular adapter (630141, etc.) is properly installed and secured.
Connector Installation
- Position the Titanium Standard Connector onto the Angular Adapter (630141, etc.).
- Align the connector with the internal thread of the angular adapter.
- Carefully screw the connector into the internal thread until fully seated.
- Verify complete and passive seating of the component.
Prosthetic Assembly
- Position the Plastic Sheath (687030) onto the connector according to the restorative protocol.
- Install the Titanium Base (690760, etc.) as required for the prosthetic design.
- Insert the Titanium Prosthetic Screw (700229).
- Tighten the screw using a compatible 1.25 mm hex driver.
- Apply the torque recommended by the prosthetic protocol and implant system manufacturer.
- Verify stability, passive fit, and correct prosthetic positioning.
Final Restoration
The Titanium Standard Connector may be used in:
- Full-arch restorations
- Implant-supported bridges
- Fixed screw-retained prostheses
- Multi-unit prosthetic restorations
- Angular correction restorations
After final installation:
- Verify occlusion
- Confirm passive fit
- Check prosthetic stability
- Ensure proper access channel sealing according to clinical protocol
Removal Procedure
- Remove the access channel filling material if present.
- Using a 1.25 mm hex driver, loosen the Titanium Prosthetic Screw (700229).
- Remove the prosthetic restoration.
- Carefully remove associated prosthetic components if required.
- Inspect all components before reuse or replacement.
Cleaning and Sterilization
- Remove all manufacturing residues and contaminants.
- Clean using approved medical instrument cleaning procedures.
- Rinse thoroughly with distilled or deionized water.
- Dry completely before sterilization.
- Sterilize before use in a steam autoclave: Temperature: 135°C (274°F)
- Follow validated sterilization protocols and local regulatory requirements.
Warnings and Precautions
- For professional dental use only.
- Use only with compatible angular adapters and prosthetic components.
- Verify passive fit before final fixation.
- Do not use damaged or deformed components.
- Follow recommended prosthetic tightening protocols.
- Ensure complete seating of all components before tightening.
- Components showing signs of wear, damage, or deformation must be replaced.
Storage
Store in a clean, dry environment protected from contamination, moisture, and mechanical damage.