Product Description
The Titanium Sheath for Multi Unit M2.0 is a precision prosthetic component designed for the fabrication of screw-retained temporary and permanent implant restorations. The sheath provides a stable and durable restorative interface for use with compatible standard connectors, ensuring accurate prosthetic positioning and long-term restoration stability.
Manufactured from high-quality Ti6Al4V medical titanium alloy ASTM F136, the titanium sheath offers exceptional biocompatibility, mechanical strength, corrosion resistance, and long-term clinical reliability.
The component is designed without an anti-rotation element and connects directly to the Standard Connector (604040, etc.) using a Titanium Prosthetic Screw M2 UNF (700229). This design provides flexibility during laboratory and clinical fabrication of screw-retained restorations.
The Titanium Sheath is intended for use in the manufacture of both temporary and permanent implant-supported restorations on fully osseointegrated implants.
Its precision-machined geometry supports accurate prosthetic fit and facilitates incorporation into conventional and CAD/CAM restorative workflows.
Suitable for:
- Temporary screw-retained restorations
- Permanent screw-retained restorations
- Single-unit restorations
- Implant-supported bridges
- Full-arch restorations
- Fixed implant prosthetics
- CAD/CAM restorative workflows
- Oral implantology applications
Specifications
- Product type: Titanium sheath for multi-unit restoration
- Diameter: 4.0 mm
- Body height: 10.0 mm
- Shoulder height: 0.5 mm
- Anti-rotation feature: None
- Material: Ti6Al4V medical titanium alloy ASTM F136
- Connection type: Standard connector interface
- Fixation screw: Titanium Screw M2 UNF (700229)
- Driver compatibility: 1.25 mm hex key
- Restoration type: Temporary and permanent screw-retained restorations
- Sterilization: Fully autoclavable
Compatible Components
- Standard Connector (604040, etc.)
- Titanium Prosthetic Screw M2 UNF (700229)
- 1.25 mm Hex Driver
- Screw-Retained Prosthetic Restorations
Indications for Use
Intended for use in the fabrication and fixation of implant-supported restorations during:
- Temporary restorative procedures
- Permanent restorative procedures
- Single-tooth restorations
- Implant-supported bridges
- Full-arch rehabilitations
- Screw-retained prosthetic restorations
- Implant restorative procedures
Sterilization
The component must be sterilized before use in an autoclave at: 135°C (274°F)
Advantages
- Designed for temporary and permanent restorations
- Direct connection to standard connector systems
- Compatible with M2 UNF prosthetic screw systems
- Precision-machined prosthetic interface
- Suitable for conventional and CAD/CAM workflows
- High-strength Ti6Al4V ASTM F136 titanium construction
- Excellent biocompatibility
- Outstanding corrosion resistance
- Reliable restoration stability and retention
- Smooth surface for precise laboratory processing
- Fully autoclavable
- Designed for predictable long-term implant prosthetic outcomes
Reviews
There are no reviews for this product, be the first to leave your review.
Titanium Sheath for Multi Unit M2.0
Intended Use
The Titanium Sheath for Multi Unit M2.0 is intended for the fabrication and fixation of screw-retained temporary and permanent implant-supported restorations. The component serves as a prosthetic interface between the restoration and the Standard Connector (604040, etc.), providing stable support and retention for implant prostheses.
The sheath is designed for use on fully osseointegrated implants in single-unit, multi-unit, and full-arch restorative procedures.
Indications
The Titanium Sheath for Multi Unit M2.0 is indicated for:
- Temporary screw-retained restorations
- Permanent screw-retained restorations
- Single-tooth restorations
- Implant-supported bridges
- Full-arch restorations
- Fixed implant prostheses
- CAD/CAM restorations
- Implant rehabilitation procedures
Compatible Components
- Standard Connector (604040, etc.)
- Titanium Prosthetic Screw M2 UNF (700229)
- 1.25 mm Hex Driver
Product Specifications
- Diameter: 4.0 mm
- Body Height: 10.0 mm
- Shoulder Height: 0.5 mm
- Anti-Rotation Feature: None
- Material: Ti6Al4V Medical Titanium Alloy ASTM F136
Clinical and Laboratory Procedure
Preparation
- Verify compatibility of all prosthetic components.
- Inspect the titanium sheath for damage, deformation, or contamination.
- Ensure all components are properly cleaned and sterilized before use.
Restoration Fabrication
- Position the Titanium Sheath onto the Standard Connector (604040, etc.).
- Verify complete seating of the sheath on the connector.
- Incorporate the sheath into the temporary or permanent restoration according to the selected laboratory protocol.
- Fabricate the restoration using conventional or CAD/CAM techniques.
- Verify passive fit and proper prosthetic alignment.
Clinical Installation
1. Seat the completed restoration onto the implant-supported prosthetic platform.
2. Insert the Titanium Prosthetic Screw M2 UNF (700229).
3. Tighten the fixation screw using a compatible 1.25 mm hex driver.
4. Apply the torque recommended by the implant system and restorative protocol.
5. Verify complete seating and stability of the restoration.
6. Check occlusion and adjust as required.
Final Restoration Verification
Before completion of treatment:
- Verify passive fit of the restoration.
- Confirm complete seating of the titanium sheath.
- Check restoration stability.
- Verify proper occlusal contacts.
- Seal the screw access channel according to the restorative protocol.
Removal Procedure
1. Remove the restorative material covering the screw access channel.
2. Loosen the Titanium Prosthetic Screw M2 UNF (700229) using a 1.25 mm hex driver.
3. Remove the prosthetic restoration.
4. Inspect the titanium sheath and associated components before reuse or replacement.
Cleaning and Sterilization
- Remove all laboratory residues and contaminants.
- Clean using approved medical device cleaning procedures.
- Rinse thoroughly with distilled or deionized water.
- Dry completely before sterilization.
- Sterilize before use in a steam autoclave: Temperature: 135°C (274°F)
- Follow validated sterilization procedures and local regulatory requirements.
Warnings and Precautions
- For professional dental use only.
- Use only with compatible Standard Connectors (604040, etc.).
- Use only with Titanium Prosthetic Screw M2 UNF (700229).
- Verify complete seating before final tightening.
- Do not use damaged or deformed components.
- Follow recommended prosthetic torque values.
- Components showing signs of wear, deformation, or damage must be replaced.
Storage
Store in a clean, dry environment protected from contamination, moisture, and mechanical damage.
CadCam