Product Description
Prosthetic Set Angular Multi-Unit for Implant H2.1
The Prosthetic Set Angular Multi Unit 17° and 30° for Implant H2.1 is a comprehensive prosthetic solution designed for the restoration of osseointegrated implants with a Slim Platform H2.1 connection. The system is intended for screw-retained implant-supported restorations and provides clinicians and dental laboratories with all essential components required for impression taking, laboratory procedures, digital workflows, and the fabrication of temporary and permanent prosthetic restorations.
The 17° and 30° angular design allows correction of implant angulation, improves prosthetic positioning, facilitates screw-channel alignment, and enhances esthetic outcomes in challenging clinical situations.
Manufactured from high-quality medical-grade titanium alloy Ti6Al4V ASTM F136 and biocompatible dental polymers, the components provide exceptional mechanical strength, corrosion resistance, precision fit, and long-term clinical reliability.
The prosthetic set is designed for use with H2.1 implant platforms and supports single-unit, multi-unit, and full-arch screw-retained restorations.
Set Contents
1. Titanium Angular Adapter 17°or 30°
Angular multi-unit adapter designed to correct implant angulation and provide an optimized prosthetic platform for screw-retained restorations.
2. Titanium Esthetic Connector for Adapter
Precision-machined titanium esthetic connector designed for direct connection to the angular adapter and support of prosthetic restorations.
3. Open Tray Transfer for Esthetic Connector Abutment
Impression transfer component for accurate open-tray implant-level and abutment-level impressions.
4. Titanium Sheath for Titanium Esthetic Abutment
Titanium sleeve for fabrication of custom screw-retained restorations and CAD/CAM prosthetic structures.
5. Plastic Sheath for Titanium Esthetic Abutment
Castable plastic sleeve used for laboratory fabrication of customized prosthetic restorations.
6. Titanium Esthetic Abutment Analog
Laboratory analog for accurate model fabrication and restoration processing.
7. Long Fixation Screw for Transfer
Long prosthetic fixation screw used to secure impression transfers during open-tray impression procedures.
Features and Benefits
- 17°, 30° angulation correction for improved prosthetic positioning
- Designed specifically for Slim Platform H2.1 implants
- Supports screw-retained restorations
- Suitable for single-unit and multi-unit restorations
- Ideal for full-arch restorations
- Facilitates accurate impression procedures
- Supports conventional and digital workflows
- Compatible with CAD/CAM restorative techniques
- Precision-machined components for accurate fit
- Excellent mechanical stability and retention
- High-strength Ti6Al4V ASTM F136 titanium construction
- Outstanding biocompatibility and corrosion resistance
- Comprehensive restorative solution in one set
Indications for Use
The Prosthetic Set Angular Multi Unit 17° for Implant H2.1 is indicated for:
- Screw-retained restorations
- Angulated implant restorations
- Implant-supported crowns
- Implant-supported bridges
- Full-arch restorations
- Multi-unit prosthetic restorations
- CAD/CAM restorations
- Conventional laboratory restorations
- Digital implant workflows
Sterilization
- All titanium components are supplied non-sterile and must be sterilized before clinical use.
- Sterilization should be performed in a steam autoclave at: 135°C (274°F)
- Follow validated sterilization procedures and local regulatory requirements before use.
Applications
- Implant prosthetics
- Esthetic implant restorations
- Full-arch rehabilitation
- Angulated implant correction
- Multi-unit restorations
- Digital dentistry workflows
- CAD/CAM prosthetic fabrication
- Permanent screw-retained restorations
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Prosthetic Set Angular Multi-Unit for Implant H2.1
Intended Use
The Prosthetic Set Angular Multi-Unit 17°, 30° for Implant H2.1 is intended for the restoration of osseointegrated implants using screw-retained prosthetic restorations. The system provides a complete solution for impression taking, laboratory procedures, CAD/CAM workflows, and fabrication of temporary and permanent implant-supported restorations.
The 17°, 30° angular correction allows compensation for implant angulation, improves prosthetic positioning, optimizes screw access channel orientation, and facilitates esthetic and functional restorative outcomes.
The system is designed for use with Slim Platform H2.1 implants and is suitable for single-unit, multi-unit, and full-arch restorations.
Indications
The Prosthetic Set Angular Multi Unit 17°, 30° for Implant H2.1 is indicated for:
- Screw-retained restorations
- Angulated implant restorations
- Implant-supported crowns
- Implant-supported bridges
- Full-arch restorations
- Multi-unit restorations
- Immediate loading protocols when clinically indicated
- CAD/CAM restorations
- Conventional laboratory restorations
- Digital implant workflows
Clinical Procedure
1. Angular Adapter Installation
- Confirm successful osseointegration of the implant.
- Remove the healing component if present.
- Clean and inspect the implant connection.
- Position the 17° Titanium Angular Adapter onto the H2.1 implant.
- Verify complete seating and correct orientation.
- Tighten according to the recommended clinical protocol.
2. Esthetic Connector Installation
- Position the Titanium Esthetic Connector onto the Angular Adapter.
- Verify complete seating and correct orientation.
- Tighten according to the prosthetic protocol.
- Confirm stability of the assembly.
3. Impression Procedure
- Open Tray Technique
- Connect the Open Tray Transfer to the Esthetic Connector.
- Secure the transfer using the Long Fixation Screw.
- Verify proper seating radiographically if necessary.
- Modify the impression tray to allow screw access.
- Take the impression using an appropriate impression material.
- After material setting, loosen the fixation screw.
- Remove the impression together with the transfer.
4. Laboratory Procedure
Master Cast Fabrication
- Connect the Titanium Esthetic Abutment Analog to the transfer within the impression.
- Pour the master model according to laboratory protocol.
- Verify accurate analog positioning.
Restoration Fabrication
- Select the Titanium Sheath or Plastic Sheath depending on the restoration design.
- Design the prosthetic restoration using conventional laboratory methods or CAD/CAM technology.
- Fabricate the custom prosthetic restoration.
- Verify passive fit and proper emergence profile.
5. Restoration Delivery
- Verify fit of the completed restoration.
- Seat the restoration onto the Esthetic Connector.
- Tighten fixation screws according to the recommended prosthetic torque protocol.
- Check occlusion and adjust if necessary.
- Seal screw access channels according to standard restorative procedures.
Final Restoration Verification
Before treatment completion:
1. Verify passive fit of the restoration.
2. Confirm complete seating of all prosthetic components.
3. Verify screw stability.
4. Check occlusal contacts.
5. Confirm esthetics and soft tissue adaptation.
6. Verify radiographic fit if required.
Cleaning and Sterilization
- Remove contaminants and manufacturing residues.
- Clean according to approved medical device cleaning procedures.
- Rinse thoroughly with distilled or deionized water.
- Dry completely before sterilization.
- Sterilize titanium components in a steam autoclave at: 135°C (274°F)
- Follow validated sterilization procedures and local regulations.
Warnings and Precautions
- For professional dental use only.
- Use only with compatible H2.1 implant systems.
- Verify complete seating of all components before tightening.
- Follow recommended torque values.
- Do not use damaged or worn components.
- Replace components showing signs of deformation, wear, or damage.
- Ensure passive fit of the final restoration before delivery.
- Improper use may result in prosthetic screw loosening, component damage, or restoration failure.
Storage
Store components in a clean, dry environment protected from contamination, moisture, and mechanical damage.