Product Description
The Prosthetic Set Angular Multi Unit 17° / 30° for Implant H2.43 is a comprehensive prosthetic solution designed for the restoration of osseointegrated implants with an Internal Hex H2.43 connection. The system provides clinicians and dental laboratories with all essential components required for impression taking, laboratory procedures, CAD/CAM workflows, and the fabrication of temporary and permanent screw-retained restorations.
The 17° and 30° angular correction options allow clinicians to compensate for implant angulation, optimize prosthetic positioning, improve screw-access channel orientation, and achieve superior esthetic and functional outcomes in challenging restorative situations.
Manufactured from high-quality medical-grade titanium alloy Ti6Al4V ASTM F136 and biocompatible dental polymers, the components provide exceptional mechanical strength, corrosion resistance, precision fit, and long-term clinical reliability.
The prosthetic set is specifically designed for H2.43 implant platforms and supports single-unit, multi-unit, and full-arch screw-retained restorations.
Set Contents
1. Titanium Angular Adapter 17° or 30°
Angular multi-unit adapter designed to correct implant angulation and provide an optimized prosthetic platform for screw-retained restorations.
2. Titanium Esthetic Connector for Adapter
Precision-machined titanium esthetic connector designed for direct connection to the angular adapter and support of prosthetic restorations.
3. Open Tray Transfer for Esthetic Connector Abutment
Impression transfer component for accurate open-tray implant-level and abutment-level impressions.
4. Titanium Sheath for Titanium Esthetic Abutment
Titanium sleeve for fabrication of custom screw-retained restorations and CAD/CAM prosthetic structures.
5. Plastic Sheath for Titanium Esthetic Abutment
Castable plastic sleeve used for laboratory fabrication of customized prosthetic restorations.
6. Titanium Esthetic Abutment Analog
Laboratory analog for accurate model fabrication and restoration processing.
7. Long Fixation Screw for Transfer
Long prosthetic fixation screw used to secure impression transfers during open-tray impression procedures.
Features and Benefits
- Available with 17° and 30° angulation correction
- Designed specifically for Internal Hex H2.43 implant systems
- Supports screw-retained restorations
- Suitable for single-unit, multi-unit, and full-arch restorations
- Facilitates accurate impression procedures
- Supports conventional and digital restorative workflows
- Compatible with CAD/CAM prosthetic fabrication
- Precision-machined components for exceptional fit and stability
- Improves prosthetic positioning and screw-channel orientation
- High-strength Ti6Al4V ASTM F136 titanium construction
- Excellent biocompatibility and corrosion resistance
- Comprehensive restorative solution in a single prosthetic set
Indications for Use
The Prosthetic Set Angular Multi Unit 17° / 30° for Implant H2.43 is indicated for:
- Screw-retained implant restorations
- Angulated implant restorations
- Implant-supported crowns
- Implant-supported bridges
- Full-arch restorations
- Multi-unit restorations
- Immediate loading protocols when clinically indicated
- CAD/CAM restorations
- Conventional laboratory restorations
- Digital implant workflows
Compatible Implant Systems
- UNIQUE Implants Diameters: Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm, Ø8.0 mm
- PERFECT Implants Diameters: Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
- PRIMA Implants Diameters: Ø3.3 mm, Ø3.75 mm, Ø4.2 mm, Ø5.0 mm, Ø6.0 mm
Sterilization
- All titanium components are supplied non-sterile and must be sterilized before clinical use.
- Sterilization should be performed in a steam autoclave at:135°C (274°F)
- Follow validated sterilization procedures and local regulatory requirements before use.
Applications
- Implant prosthetics
- Esthetic implant restorations
- Full-arch rehabilitation
- Angulated implant correction
- Multi-unit restorations
- Digital dentistry workflows
- CAD/CAM prosthetic fabrication
- Permanent screw-retained restorations
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Prosthetic Set Angular Multi Unit for Implant H2.43
Intended Use
The Prosthetic Set Angular Multi Unit 17° / 30° for Implant H2.43 is intended for the restoration of osseointegrated implants using screw-retained prosthetic restorations. The system provides a complete solution for impression taking, laboratory procedures, CAD/CAM workflows, and fabrication of temporary and permanent implant-supported restorations.
The 17° and 30° angular correction options allow compensation for implant angulation, improve prosthetic positioning, optimize screw access channel orientation, and facilitate esthetic and functional restorative outcomes.
The system is designed for use with Internal Hex H2.43 implants and is suitable for single-unit, multi-unit, and full-arch restorations.
Indications
The Prosthetic Set Angular Multi Unit 17° / 30° for Implant H2.43 is indicated for:
- Screw-retained restorations
- Angulated implant restorations
- Implant-supported crowns
- Implant-supported bridges
- Full-arch restorations
- Multi-unit restorations
- Immediate loading protocols when clinically indicated
- CAD/CAM restorations
- Conventional laboratory restorations
- Digital implant workflows
Clinical Procedure
1. Angular Adapter Installation
- Confirm successful osseointegration of the implant.
- Remove the healing abutment or temporary restoration if present.
- Clean and inspect the implant connection.
- Position the 17° or 30° Titanium Angular Adapter onto the H2.43 implant.
- Orient the adapter according to the planned prosthetic axis.
- Verify complete seating and proper alignment.
- Tighten according to the recommended clinical protocol.
2. Esthetic Connector Installation
- Position the Titanium Esthetic Connector onto the Angular Adapter.
- Verify complete seating and proper orientation.
- Tighten according to the prosthetic protocol.
- Confirm stability of the assembly before proceeding.
3. Impression Procedure
- Open Tray Technique
- Connect the Open Tray Transfer to the Esthetic Connector.
- Secure the transfer using the Long Fixation Screw.
- Verify complete seating clinically and radiographically if necessary.
- Prepare the impression tray to allow access to the fixation screw.
- Take the impression using an appropriate impression material.
- After setting, loosen the fixation screw.
- Remove the impression with the transfer embedded in the impression.
4. Laboratory Procedure
Master Cast Fabrication
- Connect the Titanium Esthetic Abutment Analog to the transfer inside the impression.
- Verify correct positioning.
- Pour the master cast according to laboratory procedures.
- Allow complete setting before model separation.
Restoration Fabrication
- Select either the Titanium Sheath or Plastic Sheath according to the restoration design.
- Design the prosthetic restoration using conventional laboratory methods or CAD/CAM software.
- Fabricate the restoration.
- Verify passive fit and proper emergence profile.
- Finish and polish the restoration according to laboratory standards.
5. Restoration Delivery
- Verify fit of the completed restoration.
- Seat the restoration onto the Esthetic Connector.
- Tighten prosthetic fixation screws according to the recommended torque protocol.
- Verify complete seating and stability.
- Check occlusion and make adjustments if necessary.
- Seal screw access channels using appropriate restorative materials.
Final Restoration Verification
Before treatment completion:
1. Verify passive fit of the restoration.
2. Confirm complete seating of all prosthetic components.
3. Verify prosthetic screw stability.
4. Check occlusal contacts and articulation.
5. Confirm esthetics and soft tissue adaptation.
6. Verify radiographic fit when indicated.
Cleaning and Sterilization
- Remove contaminants and manufacturing residues.
- Clean using approved medical device cleaning procedures.
- Rinse thoroughly with distilled or deionized water.
- Dry completely before sterilization.
- Sterilize titanium components in a steam autoclave at: 135°C (274°F)
- Follow validated sterilization procedures and local regulatory requirements.
Warnings and Precautions
- For professional dental use only.
- Use only with compatible Internal Hex H2.43 implant systems.
- Verify complete seating of all components before tightening.
- Follow recommended torque values.
- Do not use damaged, worn, or deformed components.
- Replace components showing signs of wear or damage.
- Ensure passive fit of the final restoration before delivery.
- Improper use may result in prosthetic screw loosening, component damage, or restoration failure.
Storage
Store components in a clean, dry environment protected from contamination, moisture, and mechanical damage.
CadCam