Product Description
Universal Philips Driver Key for Round Surgical Screw
The Universal Philips Driver Key for Round Surgical Screw is a precision surgical instrument designed for the installation and removal of round surgical screws used during dental implant procedures. Manufactured from high-quality medical-grade stainless steel, the instrument provides excellent durability, corrosion resistance, and reliable torque transmission in both surgical and restorative applications.
The driver features a precision Philips-type engagement designed specifically for compatible round surgical screws, ensuring secure retention and controlled screw manipulation during clinical procedures. Its ergonomic body allows comfortable handling and precise control, while the universal design enables use both manually and in conjunction with compatible surgical ratchets, torque wrenches, and implant driver systems.
The Universal Philips Driver Key is commonly used during implant surgery for fixation of surgical components, fixation plates, guide components, membrane fixation screws, and other implant-related procedures requiring round surgical screws with a Philips-type connection.
Designed for repeated clinical use, the instrument can be cleaned, sterilized, and reused according to standard surgical protocols.
Advantages
- Precision Philips-type engagement.
- Designed for round surgical screws.
- Secure screw retention and engagement.
- Excellent torque transmission and control.
- Manufactured from medical-grade stainless steel.
- Corrosion-resistant and durable construction.
- Ergonomic design for improved handling.
- Suitable for manual and instrument-assisted use.
- Reusable following proper cleaning and sterilization procedures.
- Compatible with a variety of surgical implant applications.
Specifications
- Product Type: Universal Philips Driver Key
- Connection Type: Philips Driver
- Material: Medical-Grade Stainless Steel
- Application: Surgical Implant Procedures
- Use: Manual and Instrument-Assisted
- Reusable: Yes
Indications
- Installation of round surgical screws.
- Removal of round surgical screws.
- Surgical implant procedures.
- Bone augmentation procedures.
- Membrane fixation procedures.
- Guided surgery component fixation.
- Oral and maxillofacial surgical procedures requiring Philips-type surgical screws.
Compatible Components
- Round Surgical Screws
- Surgical Fixation Screws
- Membrane Fixation Screws
- Guided Surgery Components
- Compatible Surgical Ratchets
- Compatible Torque Wrenches
Clinical Applications
The Universal Philips Driver Key allows clinicians to safely insert and remove round surgical screws while maintaining excellent control and precision. The instrument can be used for initial manual placement and, when appropriate, final tightening using compatible torque instruments according to the clinical protocol.
Sterilization
- Thoroughly clean the instrument.
- Remove all biological debris and contaminants.
- Rinse and dry completely.
- Sterilize using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage.
Reviews
There are no reviews for this product, be the first to leave your review.
Universal Philips Driver Key for Round Surgical Screw
Intended Use
The Universal Philips Driver Key for Round Surgical Screw is intended for the installation, tightening, loosening, and removal of round surgical screws used during dental implant surgery and oral surgical procedures.
The instrument is designed to provide secure engagement with compatible Philips-type screw heads and allows controlled torque transmission during surgical fixation procedures.
Indications
- Placement of round surgical screws.
- Removal of round surgical screws.
- Bone augmentation procedures.
- Membrane fixation procedures.
- Guided surgery procedures.
- Implant surgical procedures.
- Oral and maxillofacial surgical procedures requiring Philips-type fixation screws.
Contraindications
Do not use:
- For applications other than intended surgical procedures.
- If the instrument is damaged, bent, worn, or corroded.
- With incompatible screw designs.
- If secure engagement between the driver and screw cannot be achieved.
Warnings
- This product is intended for use only by qualified dental professionals and oral surgeons.
- Verify complete engagement of the Philips driver tip before applying torque.
- Excessive force may damage the screw, bone, fixation device, or instrument.
- Inspect the instrument before each use.
- Replace worn or damaged instruments immediately.
Precautions
- Use only with compatible round surgical screws.
- Maintain sterility throughout the procedure.
- Apply controlled force during tightening and loosening procedures.
- Avoid excessive lateral loading of the driver tip.
- Ensure proper visibility and access to the surgical site before use.
Instructions for Use
Pre-Operative Procedure
1. Inspect the Universal Philips Driver Key for cleanliness, wear, deformation, or damage.
2. Verify compatibility with the surgical screw being used.
3. Clean and sterilize the instrument before use.
4. Prepare the surgical site according to the planned procedure.
Surgical Screw Installation
1. Position the round surgical screw at the intended location.
2. Engage the Philips driver tip fully into the screw head.
3. Verify secure engagement.
4. Rotate the driver clockwise while maintaining axial pressure.
5. Continue tightening until the screw is properly seated.
6. If required, use a compatible ratchet or torque device according to the surgical protocol.
7. Verify fixation stability after placement.
Surgical Screw Removal
1. Engage the Philips driver tip completely into the screw head.
2. Apply controlled counterclockwise rotation while maintaining axial pressure.
3. Remove the screw carefully from the surgical site.
4. Inspect the screw and surrounding structures after removal.
Cleaning and Sterilization
- Thoroughly clean the instrument to remove blood, tissue residues, bone particles, and contaminants.
- Pay particular attention to the driver tip and engagement surfaces.
- Rinse thoroughly with clean water.
- Dry completely before sterilization.
- Sterilize using a validated steam sterilization cycle.
- Recommended Sterilization: Autoclave at 135°C (274°F)
- Do not use the instrument if sterility cannot be assured.
Maintenance
- Inspect the Philips driver tip regularly for wear or deformation.
- Replace the instrument if rounding, bending, corrosion, cracking, or damage is observed.
- Do not modify the instrument.
Storage
Store in a clean, dry environment protected from contamination, moisture, direct sunlight, and mechanical damage. Keep the instrument in a protective surgical tray or instrument cassette when not in use.