Motor Hex Driver Key 1.77 mm for Contra Angle
The Motor Hex Driver Key 1.77 mm for Contra Angle is a precision implantology instrument designed for controlled insertion and removal of prosthetic and implant screws during dental implant restorative procedures. The driver is intended for use with compatible implant systems requiring a 1.77 mm hex connection and is specifically engineered for motor-driven clinical applications.
The instrument features a precision-machined 1.77 mm hex working tip that обеспечивает secure engagement with implant components, allowing accurate torque transfer and stable screw handling during surgical and prosthetic procedures.
The driver is designed for use with contra-angle handpieces, providing controlled rotational performance, improved clinical efficiency, and precise access during implant restoration procedures.
Manufactured from high-quality medical-grade stainless steel, the instrument offers excellent dimensional accuracy, corrosion resistance, mechanical durability, and long-term clinical reliability.
The Motor Hex Driver Key 1.77 mm is suitable for use in implant prosthetic procedures requiring accurate screw driving performance and controlled mechanical engagement.
Suitable for:
- Implant prosthetic procedures
- Prosthetic screw insertion
- Prosthetic screw removal
- Implant restorative procedures
- Dental implant maintenance
- Oral implantology applications
The precision 1.77 mm hex design allows stable engagement with implant components and reliable torque transmission during clinical procedures.
Specifications
- Instrument type: Motor hex driver key
- Hex size: 1.77 mm
- Connection: Contra angle
- Design: Precision hex working tip
- Material: Medical-grade stainless steel
- Application: Motor-driven implant procedures
- Sterilization: Fully autoclavable
Indications for Use
Intended for:
- Implant prosthetic screw driving
- Implant screw removal procedures
- Restorative implant procedures
- Dental implant maintenance
- Prosthetic component handling
- Oral surgical implant applications
Sterilization
The instrument must be sterilized before use in an autoclave at: 135°C (274°F)
Advantages
- Precision 1.77 mm hex connection
- Stable implant component engagement
- Accurate torque transmission
- Designed for contra-angle handpieces
- High-strength stainless steel construction
- Excellent corrosion resistance
- Reliable clinical performance
- Suitable for implant restorative procedures
- Fully autoclavable
- Designed for long-term clinical durability
Reviews
There are no reviews for this product, be the first to leave your review.
Answers & questions
No questions about this product, be the first and ask your question.
Motor Hex Driver Key 1.77 mm for Contra Angle
Product Description
The Motor Hex Driver Key 1.77 mm for Contra Angle is a reusable dental implant instrument intended for use during implant restorative and prosthetic procedures. The instrument is designed for insertion and removal of implant prosthetic screws using compatible implant systems requiring a 1.77 mm hex connection.
The instrument is intended for use together with a low-speed contra-angle handpiece, allowing controlled torque transfer and stable engagement with implant components during clinical procedures.
Manufactured from medical-grade stainless steel, the driver provides high mechanical strength, dimensional precision, corrosion resistance, and long-term clinical durability.
Intended Use
The Motor Hex Driver Key 1.77 mm is intended for:
- Implant prosthetic screw insertion
- Implant prosthetic screw removal
- Restorative implant procedures
- Dental implant maintenance
- Prosthetic component handling
- Oral implantology procedures
Indications for Use
The instrument is indicated for use in dental implant restorative procedures requiring controlled mechanical engagement of prosthetic screws and implant components compatible with a 1.77 mm hex connection.
Contraindications
Do not use the instrument:
- For procedures other than intended dental implant applications
- With incompatible implant systems or incorrect hex connections
- If the instrument is damaged, bent, worn, or corroded
- Without proper sterilization before clinical use
Warnings
- The instrument must be used only by qualified dental professionals trained in implantology procedures.
- Always verify proper engagement between the driver and implant component before operation.
- Excessive torque or improper use may damage implant components or the instrument.
- Inspect the instrument before each use for wear, deformation, or damage.
- Use only compatible contra-angle handpieces and implant systems.
Precautions
- Sterilize the instrument before first use and before each subsequent use.
- Avoid excessive mechanical force during clinical procedures.
- Clean the instrument immediately after use to prevent residue accumulation.
- Follow standard implant surgical and restorative protocols.
- Use appropriate irrigation and clinical operating procedures when necessary.
Directions for Use
1. Clean and sterilize the instrument before use.
2. Attach the Motor Hex Driver Key securely to a compatible contra-angle handpiece.
3. Verify proper connection and stability.
4. Engage the 1.77 mm hex tip with the implant prosthetic screw or component.
5. Operate the contra-angle handpiece according to the implant system protocol.
6. After completion of the procedure, remove the instrument carefully.
7. Clean, disinfect, and sterilize the instrument before reuse.
Cleaning and Disinfection
Immediately after use:
- Remove visible debris and contaminants.
- Rinse thoroughly under running water.
- Clean manually or using an ultrasonic cleaner with approved medical instrument detergent.
- Dry the instrument completely before sterilization.
Sterilization
- The instrument must be sterilized before use in an autoclave at: 135°C (274°F)
- Sterilization must be performed according to standard dental sterilization procedures and local regulations.
Storage
- Store in a clean, dry environment.
- Protect from moisture and contamination.
- Store in appropriate sterilization packaging until use.