Product Description
The Plastic Abutment Round for Implant H2.43 is a precision laboratory component designed for the fabrication and casting of custom implant-supported restorations. Manufactured from high-quality Delrin® plastic, this cylindrical straight abutment serves as a pattern for creating individualized abutments in dental laboratory workflows.
The abutment features a round, shoulderless design without an internal hex, providing dental technicians with maximum flexibility when designing custom cement-retained and screw-retained restorations. It is ideal for creating personalized emergence profiles and restorative contours tailored to the patient's anatomical requirements.
Designed for use with the DMi Internal Hex H2.43 implant platform, the Plastic Abutment Round is secured to the implant using the Titanium Abutment Screw (701203) and is intended exclusively for laboratory procedures.
Features and Benefits
1. Custom Abutment Fabrication
- Designed for casting and fabrication of individualized abutments.
- Allows customization of restorative contours and emergence profiles.
- Supports both cement-retained and screw-retained restorations.
2. Round Shoulderless Design
- Cylindrical straight profile.
- No shoulder design for maximum laboratory flexibility.
- No internal hex geometry.
3. High-Quality Delrin® Material
- Easy to modify and contour.
- Excellent dimensional stability.
- Suitable for laboratory processing and casting procedures.
4. Restorative Versatility
- Supports a wide range of prosthetic indications.
- Enables fabrication of customized implant restorations.
- Compatible with conventional laboratory workflows.
Technical Specifications
- Connection: Internal Hex H2.43
- Diameter: 3.8 mm
- Height: 12 mm
- Material: Delrin® Plastic
- Design: Round, Straight, Shoulderless
- Retention Type: Cement-Retained and Screw-Retained Restorations
Compatibility
- UNIQUE Implant System Diameters: 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
- PERFECT Implant System Diameters: 4.2 mm, 5.0 mm, 6.0 mm
- PRIMA Implant System Diameters: 3.3 mm, 3.75 mm, 4.2 mm, 5.0 mm, 6.0 mm
Required Component
Used together with:
- Titanium Abutment Screw 701203
- Clinical and Laboratory Applications
- Custom abutment fabrication
- Implant-supported crowns
- Implant-supported bridges
- Cement-retained restorations
- Screw-retained restorations
- Dental laboratory prosthetic procedures
- Casting of individualized implant abutments
Advantages
- Easy customization and contouring
- Compatible with multiple DMi implant systems
- Suitable for both cement and screw-retained restorations
- Supports individualized prosthetic design
- Reliable laboratory performance
- Cost-effective restorative solution
Intended Use
The Plastic Abutment Round for Implant H2.43 is intended for dental laboratory use in the fabrication and casting of custom implant abutments and implant-supported restorations.
Professional Use Only
For use by qualified dental laboratories and dental technicians experienced in implant restorative procedures.
Reviews
There are no reviews for this product, be the first to leave your review.
Plastic Abutment Round for Implant H2.43
Intended Use
The Plastic Abutment Round for Implant H2.43 is intended for:
- Fabrication of custom cast abutments.
- Fabrication of implant-supported crowns and bridges.
- Cement-retained restorations.
- Screw-retained restorations.
- Laboratory production of individualized implant prosthetics.
Indications
Use when:
- A customized implant abutment is required.
- Implant angulation or restorative space requires a custom solution.
- Individual emergence profile design is desired.
- Cement-retained or screw-retained restorations are planned.
Required Components
- Plastic Abutment Round for Implant H2.43
- Titanium Abutment Screw (701203)
- Compatible implant analog or implant
- Standard laboratory casting equipment
Instructions for Use
1. Model Preparation
- Prepare the master model with the appropriate implant analog.
- Verify that the implant analog is securely seated within the working model.
- Inspect the model for accuracy before proceeding.
2. Abutment Placement
- Place the Plastic Abutment Round onto the implant analog.
- Verify complete seating of the abutment.
- Secure the abutment using Titanium Abutment Screw 701203.
- Hand-tighten the screw to stabilize the component during laboratory procedures.
3. Abutment Modification
- Modify the plastic abutment as necessary to achieve the desired:
- Emergence profile
- Contour
- Height
- Prosthetic support
- Ensure adequate material thickness remains during shaping.
4. Wax-Up Procedure
- Perform the wax-up directly on the plastic abutment.
- Create the desired prosthetic design.
- Verify contours, emergence profile, and restoration dimensions.
5. Casting Procedure
- Invest the completed wax pattern according to standard laboratory protocols.
- Burn out the plastic component during the casting process.
- Cast the customized abutment using appropriate dental casting alloys.
- Finish and polish the cast abutment according to laboratory standards.
6. Restoration Fabrication
- Verify the fit of the cast abutment on the implant analog.
- Fabricate the final restoration.
- Confirm proper fit, contour, and occlusion before clinical delivery.
Precautions
- For laboratory use only.
- Do not use as a definitive intraoral abutment.
- Inspect components prior to use.
- Use only compatible DMi implant systems.
- Follow standard dental laboratory procedures and safety protocols.
- Avoid excessive modification that may compromise restoration design.
Cleaning and Storage
- Store in a clean, dry environment.
- Protect from excessive heat and direct sunlight.
- Keep components in original packaging until use.
- Maintain standard laboratory cleanliness procedures.